Diode and Continuity
Range Description Remark
The approximate forward
voltage drop will be displayed
Open circuit voltage: about
1.5V
The built-in buzzer will sound
if the resistance is less than
about 30Ω
Open circuit voltage: about
0.5V
Overload Protection: 250V DC/AC rms
For continuity test: When the resistance is between 50Ω and 100Ω, the buzzer may sound or
may not sound. When the resistance is more than 100Ω, the buzzer will not sound.
Capacitance
Range Resolution Accuracy
40nF 10pF ± (8% of rdg + 10 dgts)
400nF 100pF
± (5% of rdg + 5 dgts)
4uF 1nF
40uF 10nF
100uF~2mF 100nF
Frequency
Range Accuracy
5/50/500/5K
50K/500K/5MHz
± (1.0% of rdg + 3dgts)