ASUS P5N64 WS Professional 5-45
2. Press <R> to rebuild a RAID array. The following screen appears.
3. Use the up or down arrow keys to select a RAID array to rebuild, then press
<F7>. The following conrmation message appears.
Rebuild array?
[ENTER] OK [ESC] Cancel
4. Press <Enter> to start rebuilding array or press <Esc> to cancel.
5. After the rebuild process, the Array list menu appears.
Array 4 : NVIDIA MIRROR 149.04G
- Select Disk Inside Array -
RAID Mode: Mirrored
Striping Width: 1 Striping Block: 64K
Port Index Disk Model Capacity
0.0 0 WDC1600AAJS-22PSA0 149.05G
0.1 1 WDC1600AAJS-22PSA0 149.05G
[↑↓] Select [F6] Back [F7] Finish
You will need to enter Window
®
XP/Vista and run the NVIDIA utility in order to
complete the rebuilt process.