Instruction Book
77 9829 2115 69
Timer card layout
Below figure shows the terminals of the timer card:
Timer card of the CD dryers
Supply connection (X9)
In most cases, the dryer only needs to be connected to the power supply. If not already done,
the power cable must be connected to terminals X9 as shown below.
Timer card 1900 0713 03 (cubicle 1900 5002 00 and 1900 5002 02) is suitable for supply
voltages 115 V and 230 V.
For 230 V AC: connect the supply cable to terminals 2 (line) and 5 (neutral) and place a
jumper wire between terminals 3 and 4:
For 115 V AC: connect the supply cable to terminals 2 (line) and 5 (neutral) and place a
jumper wire between terminals 2-3 and 4-5: