Technical Data
Product data
Motor voltage 36 V d.c.
Motor power 1500 W
Speed range 1000 - 3600 r/min
Torque range 55 - 150 Nm (59 - 110 ft lb)
Weight 2.8 kg (6.17 lb)
Product Power Source
This product can be used with a battery or with an electrical
power cable with a power supply unit.
Battery Compatibility
Accessory Article nr.
Battery, 36V (2.5Ah) 4211 6030 86
Charger Compatibility
Accessory Article nr.
Flex charger 4211 6083 84
Ambient Temperature
Operating temperature, charge +5 to +40 °C
(+41 to +104 °F)
Operating temperature, discharge 0 to +40 °C
(+32 to +104 °F)
Storage temperature −20 to +40 °C
(−4 to +104 °F)
Maximum Radio Output Power
Radio Technology
Frequency Range
(MHz)
Maximum Trans-
mit Power EIRP
(dBm)
Wi-Fi® 2412-2472 19.1
Wi-Fi® 5180-5320 16.6
Wi-Fi® 5500-5700 17.3
Wi-Fi® 5745-5825 13.1
Bluetooth® wire-
less technology /
Bluetooth® Low
Energy
2402-2480 13.7
Wi-Fi® is a registered trademark of Wi-Fi Alliance®
The Bluetooth® word mark and logos are registered trade-
marks owned by Bluetooth SIG,Inc.
EU SAR value
EU SAR Value: 0.26
Cable Power Supply Unit Compatibility
Accessory Article nr.
Power Supply Unit 950 8432 0840 04
Charger Temperatures
Charger operating tempera-
ture
+5 to +40 °C
(+41 to +104 °F)
Wireless LAN Information
Regulatory Do-
main
Band TxChannels
WORLD 2.4 GHz 1, 2, 3, 4, 5, 6, 7, 8,
9, 10, 11
U-NII-1 36, 40, 44, 48
U-NII-2 52, 56, 60, 64
U-NII-2e 100, 104, 108, 112,
116, 132, 136, 140
U-NII-3 -
ETSI 2.4 GHz 1, 2, 3, 4, 5, 6, 7, 8,
9, 10, 11, 12, 13
U-NII-1 36, 40, 44, 48
U-NII-2 52, 56, 60, 64
U-NII-2e 100, 104, 108, 112,
116, 120, 124, 128,
132, 136, 140
U-NII-3 149, 153, 157, 161,
165
FCC 2.4 GHz 1, 2, 3, 4, 5, 6, 7, 8,
9, 10, 11
U-NII-1 36, 40, 44, 48
U-NII-2 52, 56, 60, 64
U-NII-2e 100, 104, 108, 112,
116, 132, 136, 140
U-NII-3 149, 153, 157, 161,
165
Declarations
Liability
Many events in the operating environment may affect the
tightening process and shall require a validation of results. In
compliance with applicable standards and/or regulations, we
hereby require you to check the installed torque and rota-
tional direction after any event that can influence the tighten-
ing result. Examples of such events include but are not lim-
ited to:
• initial installation of the tooling system
• change of part batch, bolt, screw batch, tool, software,
configuration or environment
• change of air- or electrical connections
• change in line ergonomics, process, quality procedures
or practices