Service EN GTG25 F120-13
18
© Atlas Copco Industrial Technique AB - 9839 0065 01
Service
Maintenance Instructions
Service Recommendations
Preventive maintenance is recommended at regular intervals. See the detailed information on preventive
maintenance. If the product is not working properly, take it out of service and inspect it.
If no detailed information about preventive maintenance is included, follow these general guide-
lines:
■
Clean appropriate parts accurately
■
Replace any defective or worn parts
Preventive Maintenance
Service interval overview
The table below shows the recommended service intervals for this tool, including what parts to service af-
ter 350, 700 and 1000 working hours.
The 1 000 hours service must only be carried out by authorized workshop or qualified service technician.
350 hours service 700 hours service 1 000 hours service
Inspect tool visually Inspect tool visually Inspect tool visually
Change oil Change oil Change oil
Clean filters Clean filters Clean filters
Service turbine
Service spindle
Service instructions
Changing oil
WARNING Risk of severe injury
Air under pressure can cause injury.
► Always shut off the air supply when not in use or before any adjustments.
► Drain the hose of air pressure and disconnect the tool from air supply when not in use or before
any adjustments.
► Always use the correct hose size and air pressure for the tool.
Required tools:
■
Vice
■
Screwdriver TX20
■
Torque wrench
Spare parts
■
Service kit including oil syringe filled with 7ml Turbine Gearbox Oil 32
(available to order from Atlas Copco).
Torque converter
■
3 Nm = 2.2 ftlb
■
6 Nm = 4.4 ftlb