Cleaning the coarse air filter
WARNING Risk of severe injury
Air under pressure can cause injury.
► Always shut off the air supply when not in use or before any adjustments.
► Drain the hose of air pressure and disconnect the tool from air supply when not in use or before
any adjustments.
► Always use the correct hose size and air pressure for the tool.
Required tools:
■
Vice
■
Torque wrench
■
Wrench (3/8”)
■
Blow gun
Spare parts: At 1000 hours service the filter shall be replaced.
Instructions
1. Position the tool in a vice. Lock the throttle lever to the throttle handle with tape.
Disconnect the air adapter from the handle using a wrench.
Disassemble the 360-outlet adapter from the handle.
2. Disassemble the screw cap from the handle using a wrench.
Clean the coarse air filter using a blow gun.
Replace the coarse air filter if any damage or malfunction is detected.
3. Assemble the cleaned or new course air filter with the o-ring in the screw cap.
Fit the screw cap in the handle and tighten using a wrench to recommended torque.
4. Assemble the 360-outlet adapter with the o-ring to the handle.
Tighten the air adapter with the spring to the screw cap using a wrench to recommended torque.
Remove the tape.