4.5. Motor data
Table 3 Motor data
Model Type
Motor voltage supply range (V) Nominal current (A)
Service
factor
50 Hz 60 Hz 50 Hz 60 Hz
GVS 16A
1 phase Wide 180-264 1 ph 180-264 1 ph 5.4 3.6 1
3 phase Wide
200/240±10% (Δ)
380/415±10% (Y)
200/240±10% (Δ)
380/460±10% (Y)
5.0 (Δ) /
2.2 (Y)
4.3 (Δ) /
2.2 (Y)
1
GVS 25A
1 phase Wide 198-253 1 ph 198-253 1 ph 5.2 3.2 1
3 phase Wide
200/240±10% (Δ)
380/415±10% (Y)
200/240±10% (Δ)
380/460±10% (Y)
5.0 (Δ) /
2.2 (Y)
4.3 (Δ) /
2.2 (Y)
1
GVS 40A
1 phase Wide 180-264 1 ph 180-264 1 ph 8.5 10.5 1
3 phase Europe
230±10% (Δ)
400±10% (Y)
460±10% (Y)
4.7 (Δ) /
2.7 (Y)
2.7 (Y) 1
3 phase NEMA 400±10% (Y)
230±10% (YY)
460±10% (Y)
3.7 (Y)
6.4 (YY) /
3.2 (Y)
1
3 phase Wide
220/230±10% (Δ)
380/400±10% (Y)
220/230±10% (Δ)
380/400/440/460±10% (Y)
5.2 (Δ) /
3.0 (Y)
5.2 (Δ) /
3.0 (Y)
1
GVS 60A
3 phase Europe
230±10% (Δ)
400±10% (Y)
460±10% (Y)
6.6 (Δ) /
3.8 (Y)
3.6 (Y) 1
3 phase NEMA 400±10% (Y)
230±10% (YY)
460±10% (Y)
5.0 (Y)
9.0 (YY) /
4.5 (Y)
1
3 phase Wide
220/230±10% (Δ)
380/400±10% (Y)
220/230±10% (Δ)
380/400/440/460±10% (Y)
7.5 (Δ) /
4.3 (Y)
6.9 (Δ) /
4.0 (Y)
1
12/2021 - ©Atlas CopcoPage 446996022430_C