EasyManuals Logo

Atlas Copco LT2 User Manual

Atlas Copco LT2
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
Instruction book
a Increase pressure difference
b Check valve leaks
b See 5a
7 High oil consumption on LE/LT compressors
a Oil level too high
a Do not overfill crankcase. Keep level in red circle of sight-glass
b Piston ring(s) worn or broken
b Have condition of piston rings checked
8 Unit does not start
a Electrical failure
a Have electrical system checked. Check fuses and line terminals for tightness
b Overload relay cut out
b Reset overload relay. If the relay cuts out again after starting, see point 9
c Air pressure above pre-set starting pressure
c Compressor will start when air pressure is lower than pre-set starting pressure of air pressure
switch
9 Overload relay cuts out
a Overload relay incorrectly set
a Check and adjust. Reset relay
b Solenoid valve out of order
b See 1g
c Unloader plunger jammed
c See 1f
d Blow-off silencer choked
d See 2d
e Ambient temperature too high
e Improve ventilation of room
f Motor stops and starts too frequently
f See 6
g Overcurrent due to motor or compressor failure
g Consult Atlas Copco
Footnote chapter 6
1) If provided.
2920 1585 00 - 63 -

Table of Contents

Questions and Answers: