Text on image
(1) Element(s) (4) Problem Element
(2) Warning Element 2 (5) More
(3) Triggered (6) Reset
Each time an element is reset manually, this will be logged in the Element Problem Reset
counter:
Counter screen where one element was reset manually
Text on image
(1) Information (4) Element Warnings
(2) Trigger level (5) Element Problem Resets
(3) High Temperature Warnings (6) Modify
High ambient temperature
If the ambient temperature is above the factory setting (40 °C - 104 °F), a warning is triggered
and a warning icon (1) is shown on the main screen:
Main screen with high ambient temperature warning
Text on image
(1) Compressor outlet (pressure) (3) Load
(2) Warning icon (4) Menu