PREVENTIVE MAINTENANCE SCHEDULE FOR THE COMPRESSOR
The schedule contains a summary of the maintenance
instructions. Read the respective section before taking
maintenance measures.
When servicing, replace all disengaged packings, e.g.
gaskets, O-rings, washers.
For engine maintenance refer to Engine Operation
Manual.
The maintenance schedule has to be seen as a
guideline for compressors operating in a dusty
environment typical to compressor applications.
Maintenance schedule can be adapted depending on
application, environment and quality of maintenance.
Maintenance schedule Daily 50 hours after
initial start-up
Every 6 months or
500 hours
Yearly or every
1000 hours
XAMS 407 CD - XAMS 850 CD7,
XATS 377 CD - XATS 800 CD7,
XAHS 347 CD - XAHS 710 CD7,
XAVS 307 CD - XAVS 650 CD7
supplied with unit 2912 4482 05 2912 4483 06
Engine oil level Check
Condensate (11) Drain
Compressor oil level Check
Coolant level Check
Air filter vacuator valves Empty
Fuel filter water drain Drain
ABS vessel drain Drain
Electrolyte level and terminals of battery Check Check Check
Tyre pressure Check Check Check
Leaks in air-, oil- or fuel system (12) Check Check Check
Oil cooler Clean Clean
Radiator Clean Clean
(to be continued on page 45)