- 76 -
1
) Free Air Delivery (volume flow rate) is measured according to ISO 1217 ed.3 1996 annex D
Tolerance:
• +/- 5% 25 l/s (53 cfm) < FAD < 250 l/s (530 cfm)
• +/- 4% 250 l/s (530 cfm) < FAD
The international standard ISO 1217 corresponds to following national standards:
• British BSI 1571 part 1
• German DIN 1945 Part 1
• Swedish SS-ISO 1217
• American ANSI PTC9
- at unload Fuel expert kg/h 16.8 17.6 18.3 18.8
lb/h 37.0 38.8 40.3 41.4
No
Fuel expert
kg/h 16.8 17.6 18.3 18.8
lb/h 37.0 38.8 40.3 41.4
Specific fuel consumption at 100% FAD g/m
3
27.6 29.9 31.4 35.2
lb/1000 cu.ft 1.73 1.87 1.96 2.20
Typical oil content of compressed air mg/m
3
< 5 < 5 < 5 < 5
oz/1000 cu.ft < 0.005 < 0.005 < 0.005 < 0.005
Engine oil consumption (maximum) g/h 99 99 99 99
oz/h 3.49 3.49 3.49 3.49
Compressed air temperature at outlet valve °C 71 71 71 71
°F 160 160 160 160
Noise level
- Sound pressure level (LP), measured acc. to ISO 2151
under free field conditions at 7 m distance
dB(A)72727272
- Sound power level (LW) complies with 2000/14/EC dB(A) 100 100 100 100
Designation XAMS 407 CD -
XAMS 850 CD7
XATS 377 CD -
XATS 800 CD7
XAHS 347 CD -
XAHS 710 CD7
XAVS 307 CD -
XAVS 650 CD7