3 Elektronikon™ Touch controller
3.1 Controller
The Elektronikon™ Touch controller
Introduction
The controller has the following functions:
Controlling the unit
Protecting the unit
Monitoring components subject to service
Automatic restart after voltage failure (ARAVF)
Automatic control of the unit
The controller maintains the net pressure between programmable limits by automatically loading
and unloading the unit (fixed speed units) or by adapting the motor speed (units with frequency
converter).
A number of programmable settings, e.g. the unloading and loading pressures (for fixed speed
units), the setpoint (for units with frequency converter), the minimum stop time, the maximum
number of motor starts and several other parameters are taken into account.
The controller stops the unit whenever possible to reduce the power consumption and restarts it
automatically when the net pressure decreases. If the expected unloading period is too short, the
unit is kept running to prevent too short standstill periods.
A number of time based automatic start/stop commands may be programmed. Take into
account that a start command will be executed (if programmed and activated), even after
manually stopping the unit.
Instruction book
AIF999999 19

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco ZS 4 VSD and is the answer not in the manual?

Atlas Copco ZS 4 VSD Specifications

General IconGeneral
BrandAtlas Copco
ModelZS 4 VSD
CategoryPower Screwdriver
LanguageEnglish

Related product manuals