Operation and maintenance manual - EN
17. Connection of boilers DCxxSP(X), DC15EP, CxxSP and
ACxxSP with electronic regulation ACD 03/04 and a buffer
(accumulation) tank with solar heating
Function for automatically starting the burner after the
wood burns out
Old boilers version up to serial number 343500
INFO - If using electronic regulation ACD 03/04, we do not connect any set or other sensors
in the boiler.
The operation of the burner, fan and solar is controlled directly from the ACD 03/04
regulation.
System configuration of parameters: S6 = 1, S14 = 0, S15 = 1
M M
MAX
60°C
KSPF
AF
A25
KVLF
WF
(Tk)
S automatickým startem peletového hořáku po dohoření dřeva.
AGF
(Tsv)
Boční pohled
PF = Tv
VF1
VF2
filtr
filter
ventil
valve
Laddomat 22
odpad
outlet
přívod
supply
2-6 bar
10-15°C
ventil / valve
TS131 – 3/4ZA
(WATTS STS20)
tlakoměr,
přetlakový ventil,
odvzdušňovací ventil
pressure gauge,
safety valve,
deaerator
tlaková
expansní
nádoba
pressure
expansion
vessel
vyrovnávací nádrž
buffer tank
500 - 1000 l
bojler TUV
DHW boiler
ventil
valve
ventil
valve
ventil
valve
obytné místnosti
haritable rooms
ATMOS
ACD
mísící ventil
mixing valve
čerpadlo
pump
ventil
valve
filtr
filter
ARU5/10/30
22,5
°c
ATMOS
ACD
ARU5/10/30
22,5
°c
FPF = Ts
Side view
Automatic switch over to pellet burner after burning out of wood