Operation and maintenance manual - EN
MAIN menu
PARAMETERS – this is a separate menu where individual parameters and functions can be set
depending on the type of the boiler and heating system and the authorization
level.
INFORMATION – this is a separate menu where you can view the current status of individual
devices and elements on the A25 burner.
PASSWORD – this is a very important parameter, designed only for service engineers. After entering
the required password the service engineer is allowed to change some parameters
depending on the authorization level.
Basic authorization levels: User, service engineer (installer), manufacturer
Accessible parameters depending on authorization:
Customer: T1, T4, T6, S16, S17, S18, S19, Restart, Language
Service engineer:
T1,T2, T4, T5, T6, T7, T8, T10, S1, S2, S3, S6, S11, S12, S13, S14,
S15, S16, S17, S18, S19, S24, S26, S27, S28, S29, S30, S31, S32, S33, S34, S35, S36, S37,
S38, S39, S40, S41, S42, S43, S44, S45, S48, S49, S50, S51, S52, S53, S54, S55, S56, S57,
S58, S59, S60, S61, S62, S63, S64, S65, S66, S67, S68,
OffsetTS, OffsetTV, OffsetTK,
OffsetTSV, Reset, Restart, Language
Manufacturer: all
CAUTION - The customer is expressly prohibited to change parameters
or functions of the burner without consent of the manufacturer or service
engineer although some of them are not directly protected with a password.
Otherwise the manufacturer reserves the right to decline the guarantee due to an
inexpert intervention into the burner.
Particular passwords are production secret of the ATMOS Company and
the service engineer (installer) is not authorized to provide them to anybody
without the manufacturer’s consent.
INFO - After replacement of any ignition spiral the service engineer must enter
the password: 1234, which will reset the check algorithms for the ignition
spirals. Without entering of this password the ignition spirals will never be started
(activated).
Passwords and their functions
Password Authorization / function
Service engineer
Manufacturer
8118
Switching off and on the fan speed control
Locking and unlocking all parameters
1234
Reset of check algorithms for the ignition spirals