Shortly press the "Auto adjustment" key and enter the
automatic adjustment mode.
Without metal sheets being placed, Shortly press the
"Zero-sheet setting" until the Zero-sheet LED flickeres and
enter the zero-sheet study mode. Press the "Confirm" key to
save.
1. Under Auto adjustment mode: Place one single testing metal
sheet and Shortly press the "Single-sheet setting" key, and then
the 3 LED lamps flicker. Waiting for a few seconds until only
the Double-sheet LED flickering, then the single-sheet
automatic adjustment is completed.
2. Under dynamic learning mode: Shortly press the
"Single-sheet Setting" and the Single-sheet LED will flicker. At
the time the feeding control system will convey one testing
metal sheet. After finishing the convey, press the "Confirm"
key to save.
1. Under Auto adjustment mode: Place double testing metal
sheets and Shortly press the "Double-sheet Setting" key, and
then the 3 LED lamps flicker. Waiting for a few seconds until
the three LED lamps are continuously lit, then the double-sheet
automatic adjustment is completed.
2.Under dynamic learning mode: Shortly press the
"Double-sheet Setting" and the Double-sheet LED will flicker.
At the time the feeding control system will convey two stuck
metal sheets for test. After finishing the convey, press the
"Confirm" key to save.