EasyManua.ls Logo

Atosa ATFS-75 - User Manual

Atosa ATFS-75
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Gas Vertical Type Fryer
Operating Instructions
Before you begin, please read these instructions carefully to
use this product correctly, to make the product perform ideally, and
to avoid hazards.
Models: ATFS-40 / ATFS-50/ ATFS-75

Questions and Answers

  • S
    Sara LopezAug 9, 2025
    What to do if the Atosa ATFS-75 Fryer ignites the pilot light but not the main fire?
    • B
      Blake McdonaldAug 9, 2025
      If your Atosa Fryer pilot light ignites but the main fire doesn't, it could be due to several reasons. First, check if there's sufficient gas pressure in the pipe; if not, contact your local gas supplier. Second, the main fire nozzle might be blocked, in which case you should dredge the nozzle. Third, the gas control valves may be faulty and need replacement. Fourth, the pilot light and main fire might be too far apart; adjust their distance. Finally, the pilot light flame might be too low, so adjust its height.
  • B
    Brittany SuttonAug 18, 2025
    Why is there yellow flame and black smoke coming from my Atosa Fryer?
    • J
      joshuakirkAug 18, 2025
      Yellow flame and black smoke in your Atosa Fryer can be caused by several factors. One potential cause is using the wrong type of gas; try changing the gas. Another reason could be a mismatch between the nozzle aperture and the gas resources, so adjust the nozzle diameter. Insufficient air for ignition is another possibility; increase the damper opening degree. Lastly, during peak gas usage, the gas sources may fluctuate, so turn down the valve flow and increase it after the peak.
  • H
    Heather ThompsonAug 29, 2025
    What to do if I close the gas and hear a sound of fire in my Atosa ATFS-75 Fryer?
    • P
      Parker HernandezAug 29, 2025
      If you close the gas and hear a sound of fire in your Atosa Fryer, it could be due to insufficient gas pressure in the pipe, in which case you should contact the local gas supply department. Alternatively, the nozzle aperture might not match the gas resources, requiring an adjustment of the nozzle diameter. Another cause could be insufficient flow in the connection pipe, so increase the pipe’s allowable flow. Finally, the damper opening degree might be too large; adjust the damper to resolve this.

Summary

Safety Protection

Parameter Specifications

Installation and Debugging

Unpacking and Installation

Covers unpacking procedures, equipment checks, and installation site requirements.

Safety Notices and Precautions

Operating Instructions

Lighting the Pilot Light

Step-by-step guide on how to safely ignite the pilot light.

Igniting the Main Burner

Instructions for lighting the main burner, including oil requirements.

Turn Off the Valve

Procedure for safely shutting down the main burner and pilot light.

Cleaning and Maintenance

Service and Adjustments

Troubleshooting Guide

Atosa ATFS-75 Specifications

General IconGeneral
ModelATFS-75
CategoryFryer
Number of Tanks1
Tank Capacity75 lbs
Oil Capacity75 lbs
PowerGas
Temperature Range200°F - 400°F
Thermostat ControlYes
Cool ZoneYes
Exterior MaterialStainless Steel
Interior MaterialStainless Steel
MaterialStainless Steel
Drain ValveYes
Gas TypeNatural Gas or Propane
CertificationETL
Dimensions28.5" x 33" x 32.5"

Related product manuals