  • H
    harold80Aug 13, 2025
    How to fix an Atosa ATMG-24 that is not lighting?
    • V
      vstoneAug 13, 2025
      If the Atosa Griddle isn't lighting, it could be due to insufficient gas pressure in the pipe. In this case, contact your local gas supply department. Alternatively, the nozzle might be occluded, requiring you to dredge the nozzle.
  • S
    Shannon CantuAug 17, 2025
    What to do if I hear a sound of fire when I close the gas on my Atosa Griddle?
    • R
      Robert MartinAug 17, 2025
      If you close the gas and hear a sound of fire on your Atosa Griddle, it could be due to several reasons. First, there might be insufficient gas pressure in the pipe, in which case you should contact the local gas supply department. Second, the nozzle aperture may not match the gas resources, requiring you to adjust the nozzle diameter. Third, the flow of the connection pipe might not be enough; increase the pipe’s allowable flow. Finally, the damper opening degree might be too large, so adjust the damper.
  • J
    Jason TaylorAug 21, 2025
    Why does the pilot light ignite but not the main fire on my Atosa ATMG-24?
    • R
      rebecca53Aug 21, 2025
      If the Atosa Griddle ignites the pilot light but not the main fire, several factors could be at play. It could be due to insufficient gas pressure in the pipe, so contact the local gas supply department. The main fire nozzle might be occluded, requiring you to dredge the nozzle. Gas control valves might have problems, so change gas control valves. The pilot light and the main fire’s distance might be too far, adjust the distance of them. Also, the flame might be too low, adjust the height of the pilot light.
  • L
    Lauren SparksAug 25, 2025
    Why is there yellow flame and black smoke coming from my Atosa ATMG-24 Griddle?
    • G
      Gabriel MendozaAug 25, 2025
      Yellow flame and black smoke on your Atosa Griddle can occur due to several reasons. You might be using the gas of bottom, so change the gas. The nozzle diameter may not match the gas resources, adjust nozzle diameter. There might not be enough air to ignite, increase damper opening degree. Also, in the peak of using gas, sources of gas float heavy, turn down valves flow and turn it up after the peak.
  • M
    mcummingsAug 28, 2025
    How to fix Atosa Commercial Food Equipment not lighting?
    • A
      Amanda GarciaAug 28, 2025
      If your Atosa Commercial Food Equipment isn't lighting, several factors could be at play. First, there might be insufficient gas pressure in the pipe, in which case you should contact your local gas supply department. Alternatively, the nozzle could be occluded, requiring you to dredge it. Other potential issues include a loose thermocouple connection (tighten it), a damaged thermocouple (replace it), or a failure of the gas control valve (replace it).
  • M
    Matthew OwenSep 1, 2025
    What to do if I close gas and hear a sound of fire in Atosa Commercial Food Equipment?
    • A
      Amanda MillerSep 1, 2025
      If you close the gas and hear a sound of fire in your Atosa Commercial Food Equipment, it could be due to several reasons. It may be caused by insufficient gas pressure in the pipe, so you should contact the local gas supply department. Another reason might be that the nozzle aperture doesn't match the gas resources; in this case, adjust the nozzle diameter. It's also possible that the flow of the connection pipe is not enough, requiring you to increase the pipe’s allowable flow. Lastly, the damper opening degree might be too large, so adjust the damper.
  • T
    Thomas JamesSep 4, 2025
    Why does Atosa Commercial Food Equipment ignite the pilot light but not the main fire?
    • S
      scottlamSep 4, 2025
      If your Atosa Commercial Food Equipment ignites the pilot light but not the main fire, it could be due to a few reasons. There might be insufficient gas pressure in the pipe, so contact the local gas supply department. Another cause could be the main fire nozzle occlusion, which means you'll need to dredge the nozzle. It's also possible that the gas control valve has failed, requiring you to replace the gas control valves.
  • M
    marissavargasSep 8, 2025
    Why Atosa Commercial Food Equipment has yellow flame and black smoke?
    • B
      Brandy HallSep 9, 2025
      If your Atosa Commercial Food Equipment produces a yellow flame and black smoke, several factors could be the cause. You might be using gas from the bottom of the tank, in which case, replace the gas. The nozzle diameter might not match the gas resources, so adjust the nozzle diameter. Another possibility is that there isn't enough air to ignite, so increase the damper opening degree. Also, during peak gas usage, gas sources may float heavy; in this case, turn down the valve flow and turn it up after the peak.

Summary

Safety Protection

Brief Introduction

Manufacturers Authority and Responsibility

Parameter Specifications

Outline Dimensions

Provides dimensional drawings and specifications for different models of gas countertop griddles.

Information of Gas Supply and Burner

Details gas supply pressure requirements and burner specifications, including BTU output and nozzle numbers.

Transport and Storage

Installation and Debugging

Unpacking and Installation

Guides on unpacking, inspecting for damage, and the proper installation steps for the griddle.

Debugging

Explains the importance of debugging and system testing for ensuring product function and safety performance.

Safety Notices and Precautions

Operating Instructions

Lighting the Pilot Light

Step-by-step instructions for safely lighting the pilot light on the gas countertop griddle.

Igniting the Main Burner

Details how to ignite the main burner using the pilot light and adjust burner power.

Turn Off the Valve

Instructions on how to properly turn off the main burner and pilot light of the griddle.

Stove Operation

Guidance on initial stove operation, preheating, and adjusting flame size for cooking.

Exchange Main Fire Nozzle to Switch Gas Source

Procedures for changing the gas source, including nozzle replacement and pressure maintaining valve adjustment.

Adjust Air Input

Instructions on how to adjust the air input damper for optimal flame and combustion.

Cleaning and Maintenance

Troubleshooting