15
ACCUMULATION TANKS
EN
the heat-exchange surfaces of device. Quality of the heating water depends on the quality of the water
lled into the system by starting the operation and quality and amount of the water additionally lled
into the system. Quality of the water additionally lled into the system is dened in the STN 07 7401.
To prepare the D.H.W. in abuilt-in tank or an instantaneous system, it is necessary to install the sa-
fety valve of 6 bar on the cold water inlet. It is also necessary to ensure the treatment of the D.H.W.
against the limescale and dirts from the water distribution network.
Hardness of water cannot exceed 5 mval / l. Warranty does not relate to the blockage of the tank or
the ow copper exchanger by alimescale.
7. MAINTENANCE
To clean the external parts of the tank you need awet cloth and asuitable detergent. Never use
abrasive cleaners, diluents, petroleum-based cleaners, etc.
Check the tightness of joints on the ange of the HR, HRS tank at least once ayear, eventually x the
nuts. If there is untightness even after xing the nuts, replace the sealing under the ange.
Maintenance of the accumulation tank HR, HRS concerns test and replacement of the anode rod.
The magnesium anode adjusts the electric potential inside the tank to the value preventing corro-
sion of the tank. Theoretical life-time of the anode takes 2 years of operation, but it changes accor-
ding to the callosity and the chemical composition of water at the place, where the tank is used. It
is recommended to make a test every 6 months and in the case of need, to replace the anode rod.
This additional protection element should be considered as important.
Procedure of replacement of the anode rod:
1. Discharge approximately 1/3 of the water in the tank
Procedure: close the valve at the water inlet into the tank,
open the valve of hot water on the mixing tap,
open the discharge valve of the tank.
2. Undo the upper cover of the accumulation tank.
3. Use asuitable tool to screw the anode out.
4. Install anew anode and mount the dismantled parts back.
5. Fill the tank with water, pressurize it and check the tightness.
The anode must be replaced only by aspecialized service company!
8. DISPOSAL
Packaging must be disposed following the valid prescriptions.
After expiration of the lifetime it is necessary to dispose the product in conformity with the legal
prescriptions.