Factory settings
Prior to delivery the burner has been set as follows:
Generally accessible menu:
Advanced menu
” Logging ”means that the control system here stores the latest 10 fault codes. Please
also see "Trouble-shooting".
* ) Languages: 1 = Swedish, 2 = English (3 =German, 4 = Italian, 5 = French,
6 = Finnish ).Languages 3-6 will be available soon.
Menu Settings Choice Adjustable
Output option 1 = 12 kW 1, 2, 3 10-20 kW
Pellets trim 95 % 50-200 % 50 – 200 %
Burning out 90 sec. 10-600 sec.
Logging 10 – 26 Not
adjustable
Not
adjustable
Advanced menu Random number + 5
Advanced menu Factory settings Min. – max. Unit
Output settings 12, 15, 18 10 - 20 Kilowatt
Ignition settigns 170 g 50 – 300 % g/%
Test-blowing
time 15 0-60 sec.
Transitional time 240-480 60 - 600 sec.
Transitional feeding 15 10-50 %.
Blow-cleaning time 15 10 - 600 sec.
Fire sensitivity 50 40-80 %
Selected thermostat External Extern./Intern.
Language *) ENGLISH
Pellet trim/Energy 1100 0-2000 g/6 min.
Operating time, feeder 0 hours.
Test Auto/Manual
Settings see Advanced
Menu / Logging saves the fault codes see Advanced
11