Cleaning and maintenance
NOTE:
Always keep the ash in closed containers of non-combustible material.
Maintenance once per year or when needed (by the skilled person)
Attention, the grate of the burner will start to move out!
the main boiler switch.
The burner must be cleaned after each pellet consumption of 2000kg. This presuposses that
the boiler can take up the corresponding amount of ash and that the pellets of a good quality
are burnt.
It is also recommended to clean up the boiler exchanger parts at least two times a month.
1. Clean the burners pellet intake with a bottle brush or other suitable tool.
2. Scrape the ignition plate and grate clean and clean out the holes in the grate.
Iniciate a burn down via the menu push bottons and wait until the fuel in the burner is
burned out. Open the door with burner at cca 90° angle, via menu step out from the burn out
mode. When the grate is in its
outmost possition, turn the burner operation off by switching off
1. Remove the burner hood and clean the photocell with a rag and smooth abrasive (tooth
paste). Be careful with the ribbon cable for display and push-bottons!
2. Clean the fan blades. The best way is to carefully blow them with compressed air.
3. Unscrew the grate sides and the ignition hearth plate and disconnect the cables for the
ignition spiral/coil.
4. Clean the space behind the ignition hearth plate; brush the grate clean.
5. Re-install all parts.
6. Clean the pellet storage bin and the pellet feeder from the dust and fines.
7. Check the condition of the pellet feeding hose.
8. Operate the pellet feeder via a wall socket (230V~) and let it feed pellets.
9. Adjust/trim the amount of pellets supplied.