CO Alarm Model Number (Located on the back of alarm):
CO Alarm Assembly Number (Located on back of alarm):
Date of Manufacture (Located on back of alarm):
Date of Purchase:
Where Purchased:
By KIDDE
Battery Operated
Carbon Monoxide
Alarm
Users Guide
MODEL: KN-COPP-B
ASSEMBLY: 900-0140
MODEL: KN-COB-B
ASSEMBLY: 900-0143
For questions concerning your Carbon Monoxide Alarm,
please call our Consumer Hotline at 1-800-654-9677.
Please have the following information ready when calling:
Battery operated CO alarm
With Digital Display and
Peak Level memory
Battery operated CO alarm
without Digital display
MODÈLE: KN-COPP-B
ASSEMBLAGE: 900-0140
MODÈLE: KN-COB-B
ASSEMBLAGE: 900-0143
Pour toute question concernant votre alarme de CO,
veuillez téléphoner à la ligne de service au consommateur au 1-800-654-9677.
Alarme de CO fonctionnant sur
pile avec afficheur numérique et
mémoire de niveau maximum
Alarme de CO fonctionnant sur
pile avec afficheur numérique et
mémoire de niveau maximum
N
0
de modéle d’alarme de CO (inscrit à l’arrière de l’alarme):
N
0
de série (situé à l’arrière de l’alarme):
Date de fabrication (situé à l’arrière de l’alarme):
Date d’achat:
Endroit de l’achat:
Veuillez avoir les renseignements
suivants à portée de la main quand vous appelez:
Par KIDDE
Fonctionnant sur pile
ALARME DE MONOXYDE
DE CARBONE
Manuel de l’utilisateur
810-2066
REV AO702
810-2066
REV AO702
ATTENTION Please take a few minutes to thoroughly read this manual which
should be saved for future reference and passed on to any subsequent owner.
ATTENTION Please take a few minutes to thoroughly read this manual which
should be saved for future reference and passed on to any subsequent owner.
CSA 6.19-01
CSA 6.19-01
Question and Answer IconNeed help?

Do you have a question about the Atwood KN-COPP-B and is the answer not in the manual?

Summary

Carbon Monoxide Overview

Atwood Product View

Product Diagrams

Visual representations of the Atwood CO alarm models.

Installation and Setup

Quick Set Up

Step-by-step guide for initial battery installation and unit activation.

Installation Instructions

Detailed instructions for mounting and placement of the CO alarm.

Where NOT to Install

Guidelines on unsuitable locations for CO alarm installation.

Features and Operation

Digital Display - CO Levels

Explains the digital display showing CO concentration in PPM.

Peak Level Display

Describes how the unit stores and displays peak CO concentration readings.

Other Displays and Meanings

Details various symbols and meanings displayed by the unit.

Resetting Peak Level Reading

Instructions on how to clear the peak CO level readings.

Sensor Malfunction

Identifies issues related to sensor malfunction and unit replacement.

Test;Reset Button Functionality

Explains the operation and purpose of the test/reset button.

Alarm and Status Lights

Describes the meaning of the red alarm and green operate lights.

Battery Management

Battery Installation and Replacement

Instructions for installing new batteries and replacing depleted ones.

Emergency Response and Symptoms

What to Do If the Alarm Sounds

Immediate actions to take when the CO alarm is triggered.

Symptoms of CO Poisoning

Details symptoms associated with different levels of carbon monoxide exposure.

Care and Maintenance

Keeping the CO Alarm in Good Working Order

Simple steps for regular cleaning and testing of the CO alarm.

Environmental Precautions

Advises on avoiding substances that can affect sensor performance.

Troubleshooting and Support

Troubleshooting Guide

Table listing common problems, their causes, and recommended actions.

Frequently Asked Questions

Answers common user queries about the CO alarm.

Technical Information and Warranty

Wall Mounting Template

A guide for correct wall installation positioning.

Product Specifications

Technical details including power, sensor, accuracy, and dimensions.

Limited Warranty

Information on the product's warranty coverage and terms.

Summary

Carbon Monoxide Overview

Atwood Product View

Product Diagrams

Visual representations of the Atwood CO alarm models.

Installation and Setup

Quick Set Up

Step-by-step guide for initial battery installation and unit activation.

Installation Instructions

Detailed instructions for mounting and placement of the CO alarm.

Where NOT to Install

Guidelines on unsuitable locations for CO alarm installation.

Features and Operation

Digital Display - CO Levels

Explains the digital display showing CO concentration in PPM.

Peak Level Display

Describes how the unit stores and displays peak CO concentration readings.

Other Displays and Meanings

Details various symbols and meanings displayed by the unit.

Resetting Peak Level Reading

Instructions on how to clear the peak CO level readings.

Sensor Malfunction

Identifies issues related to sensor malfunction and unit replacement.

Test;Reset Button Functionality

Explains the operation and purpose of the test/reset button.

Alarm and Status Lights

Describes the meaning of the red alarm and green operate lights.

Battery Management

Battery Installation and Replacement

Instructions for installing new batteries and replacing depleted ones.

Emergency Response and Symptoms

What to Do If the Alarm Sounds

Immediate actions to take when the CO alarm is triggered.

Symptoms of CO Poisoning

Details symptoms associated with different levels of carbon monoxide exposure.

Care and Maintenance

Keeping the CO Alarm in Good Working Order

Simple steps for regular cleaning and testing of the CO alarm.

Environmental Precautions

Advises on avoiding substances that can affect sensor performance.

Troubleshooting and Support

Troubleshooting Guide

Table listing common problems, their causes, and recommended actions.

Frequently Asked Questions

Answers common user queries about the CO alarm.

Technical Information and Warranty

Wall Mounting Template

A guide for correct wall installation positioning.

Product Specifications

Technical details including power, sensor, accuracy, and dimensions.

Limited Warranty

Information on the product's warranty coverage and terms.

Atwood KN-COPP-B Specifications

General IconGeneral
Power Source3 AA Batteries
Sensor TypeElectrochemical
Test ButtonYes
Low Battery IndicatorYes
Alarm Sound Level85 dB at 10 feet
Alarm TypeAudible
Operating Temperature40°F to 100°F (4°C to 38°C)
Operating Humidity10% to 95% non-condensing
Dimensions5.75 x 3.75 x 1.5 inches