TH114 400-114-000-C 1/3/07 1/2
Aube's TH114 non-programmable thermostat can be used to control
the ambient air temperature or floor temperature. You can select
among the following temperature control modes:
1
The thermostat displays the percentage use of heating required to maintain the desired
temperature. For example, is displayed when heating is at 40 percent.
2
GFI appears when the ground fault protection has triggered.
3
Place the thermostat in Standby to cut power to the heater when it is not in use (e.g. in
summer).
4
To reset the ground fault protection, switch the thermostat to Standby and back to On.
The configuration switches are located at the back of the control
module (faceplate).
2.1 Temperature Display (S1)
The S1 switch is used to select between °C (default) and °F.
2.2 Temperature Control Mode (S2)
This switch is used to select the temperature control mode.
n Refer to the installation instructions of the power base.
o Insert the tabs at the top of the control module in the slots at the
top of the power base.
p Secure the control module using the captive screw underneath
the base.
NOTE: Keep the thermostat's air vents clean and unobstructed at all
times.
Upon power-up, the thermostat undergoes a series of
tests before displaying the actual (measured) tempera-
ture.
The measured temperature is below the thermostat’s dis-
play range. Heating is activated.
The measured temperature is above the thermostat’s dis-
play range. Heating is deactivated.
Verify the thermostat and sensor connections.
n
Description
1.
A mode: controls and displays the ambient air temperature
F mode: controls and displays the floor temperature using
an external temperature sensor
AF mode: controls and displays the ambient air temperature
maintains the floor temperature within desired
limits using an external temperature sensor
Display
% use of heating 1 to 24% 25 to 49% 50 to 74% 75 to 99% 100%
o
Configuration
2.
Backlight button
Temperature
adjustment button
On/Standby switch
3,
4
Heating
indicator
1
Actual or setpoint
temperature
Arrow appears
when the setpoint
is displayed
Ground fault indicator
2
Unoccupied mode
indicator
F: To select the F mode
AF: To select the A or AF mode (default)
p
Installation
3.
q
Power-up
4.
r
Error Messages
5.
Control module
Power base
Air vents
Air vents
TH114
User Guide
Non-programmable Thermostat
400-114-000-C (TH114 - mode A) ENG.fm Page 1 Thursday, March 1, 2007 11:53 AM
Question and Answer IconNeed help?

Do you have a question about the Aube Technologies TH114 and is the answer not in the manual?

Aube Technologies TH114 Specifications

General IconGeneral
BacklightNo
BatteryNo
Hold FeatureYes
Power Supply24VAC
ControlElectronic

Summary

Description

A mode

Controls and displays the ambient air temperature.

F mode

Controls and displays floor temperature using an external sensor.

AF mode

Controls ambient air and maintains floor temp within limits.

Installation

Power-up

Error Messages

LO

Measured temperature below display range; heating activated.

HI

Measured temperature above display range; heating deactivated.

Er

Verify thermostat and sensor connections.

Backlight

Temperature Display and Setting

Setpoint Temperature

Displays actual temp; press buttons to view or change setpoint.

Floor Temperature Limits

Sets min/max floor temp limits for AF mode.

Technical Specifications

Warranty

Customer Assistance

Related product manuals