22
XX
SET SET
SET
SET
XX
3
LCK
on
PrG
off
PrG
Figure 12. Single-step mode flow chart.
In single-step mode, the save and recall function (Section 9) can still work. But the
change can only be applied to C-1, i.e., you can only store your current set temperature
to the C-1 in a selected recipe, or recall the C-1 temperature from a selected recipe to
the current set temperature. Other data will remain in the memory of controller but is not
accessible under the single-step mode. To exit the single-step mode, you only need to
change the “PrGvalue to “on”.
Note 1: In older versions, it may show PrG options as “yor “n”, instead of on”, “off”. To
enter single-step mode, please select “n”.
Note 2: Smoke generator socket and settings (R1, R2 parameters) are disabled under
single-step mode. You need to power your smoke generator to separate power outlet
and control it manually.
11. Examples
a. Store your program as a recipe (Program Mode)
Before you input your program, check the PrG = on (accessed by LCK code “3”). Press
SET briefly, and enter the program below:
C-1=120, E-1=t, t-1=2.0;
C-2= 290, E-2= F, F-2=160;
C-3=130, E-3=t, F-3=30.0.
You can leave the rest of steps as their default values.
To store in program to recipe b1, long press SET key, set LCK=2, choose b1, and press
SET again to confirm and exit. Now the controller is back to the normal operating mode.
It will run on this current program, which has just been saved as recipe b1.
b. Recall a recipe to the current program (Program Mode)
Before you input your program, check the PrG = on (accessed by LCK code “3”). Long
press SET, set LCK=2, choose b1, press set to exit.
Then recipe b1 is recalled back as the current program. The controller is back to the
normal operating mode and will start run the current program.
c. Store your program as recipe (Single-step Mode)