Third option: Display “Fn” “F1-5 Fan Rotation Mode”: release the power button. This simply
runs the fan only and is great for good air circulation on hot days. You may use the up or down
on the remote or LCD control to increase or decrease the fan speed.
Fourth option: Display “r1” “Remote matching” release the power button. This allows you to
pair the remote if ever required. press any key on the remote control within 10 seconds and the
remote control will be paired successfully.
Fifth option: Display “rP” “Remote pump oil” release the power button. This is to prime the
fuel using the remote control. This function is very handy just after installation or if you ever run
out of fuel and need to prime it again. the screen will display “20”, which means this function
will be turned off 20 minutes later. At this time, you can use the remote control – simply go to
the fuel pump and press the power button on the remote control – The pump should start
ticking = Once it does, go to the fuel tank and you should see fuel moving into the fuel filter.
Follow the fuel as it moves down the fuel line and through the fuel pump. Once it arrives 10cm
from the unit press the power button on the remote again to stop the fuel from pumping. Go
back to the LCD and short press the power button to turn it off and then short press the power
button again to turn it back on. The unit should now start in normal operation.
Sixth option :Display “LA”: Language selection” release the power button. Use the up and down
keys to select the language, then push the power button and the unit will remain on your
selection. Options are: CH(Chinese) ,EN(English) ,RU(Russian) ,“- -” (No voice)“BP” (beep
only.)
4. The information button on the left of the LCD can be short pressed to view/ room
temperature/ the surface temperature on unit body and main power source voltage.
5. Automatic start timer function. The timer function allows you to set a start time from 1
minute to 99 hours and 59 minutes to switch on or off.
To set the timer to automatically turn ON: Press and hold the UP button on the LCD
control panel until it displays 00:00 then let go. You can now use the up and down buttons to set
the number of hours and minutes you would like the heater to automatically start up in. You can
set it to start in a minimum of 1 minutes (00:01) or a maximum of 99 hours and 59 minutes
(99:59)
To set the timer to automatically turn OFF: Press and hold the DOWN button on the LCD
control panel until it displays 00:00 then let go. You can now use the up and down buttons to set
the number of hours and minutes you would like the heater to shut down in. You can set it to
shut down in a minimum of 1 minutes (00:01) or a maximum of 99 hours and 59 minutes (99:59)