SPECIFICATIONS FOR USE
The Cebilon Platinum reverse osmosis system meets the NSF/ANSI Standard 58
(US standard for point of use (POU) reverse osmosis systems (RO)) for
performance standards veried with conrmed test data.
Do not use water for this system that is microbiologically unsafe, that has
not been suciently disinfected before or after operation or that is of
unknown quality.
Cebilon Platinum reverse osmosis system contains components that need
to be replaced regularly to eciently lter the dissolved solids
(TDS) from
the water. To check the eciency of the system, check the water in the
system regularly.
Please also replace the lters according to the specied replacement
intervals.
• Water inlet pressure for systems without pressure pump (min/max):
3 - 5 bar
• Water inlet pressure for systems with pressure pump (min/max):
1 - 3 bar
• Clean water production of the reverse osmosis membrane:
75 gpd (283,4 l/d)
• Clean water tank capacity: 2.2 gallons (approx. 8 liters)
• Inlet of total dissolved
solids (TDS): max. 1250 ppm
• Average salt ltration: 97 - 98 %
• Water inlet temperature (min/max): 5 - 45 ºC
• Power supply (system with pressure pump): Input: 220 - 240 VAC
/ 50/60Hz; Output: 24 VDC / 0.8 (nom) max. 1.2 A
TECHNICAL DATA SHEET