RESET of the regulator
MASTER RESET of the regulator
Special situations
Pressing the RESET buon ( ) causes the me and day seng to be erased, and the
regulator to be restarted.
The MASTER RESET funcon restarts the regulator and restores factory sengs. This
funcon is invoked by pressing the and RESET buons simultaneously.
NOTE: All user-dened programs will be erased!
• When 3 consecuve transmissions (aer 15 minutes) from the AURATON R25 RT
regulator and/or the T-2 thermometer are lost, an error is signalled on the RT receiver
(LED ashing connuously red and green). The RT receiver starts execung the ON
- OFF cycle memorised during the last 24 hours of operaon unl the problem is
removed.
• When both signals return (from the AURATON R25 RT regulator and the T-2
thermometer), the error is cancelled and the receiver enters its normal mode of
operaon.
• When only the T-2 thermometer signal returns, the receiver uses the last memorised
setpoint value and maintains it while signalling the error.
• When the H-1 handles, the T-2 thermometer and the AURATON R25 RT regulator (the
temperature is measured with the T-2 thermometer) are paired with the receiver,
then maintaining the work cycle from the last 24 hours occurs only aer losing the
signal from the T-2 thermometer. When only the signal from the AURATON R25 RT is
missing, the RT receiver automacally maintains the last memorised setpoint from the
AURATON R25 RT regulator and also signals an error.
• When you have only the H-1 handles and the T-2 thermometer paired with the RT
receiver without the AURATON R25 RT regulator, the RT receiver maintains a constant,
factory-dened temperature of 20°C. If you pivot any window equipped with the H-1
handle paired with the receiver, a temperature of 17°C is maintained. If you open
any window equipped with the H-1 handle paired with the RT receiver, the receiver
switches o the heang device, but will switch it back on when the temperature falls
below 7°C.