9
Cooperation of the AURATON RT receiver with the
AURATON R25 RT regulator and/or the AURATON T-2 thermometer
The operaon of temperature regulaon in the receiver is based on the binary algorithm
(on/o) using one or two sensor elements.
The AURATON R25 RT regulator allows for seng and/or monitoring the temperature.
The AURATON T-2 thermometer provides informaon about the current temperature
only, without the capability of changing it manually.
A) The manual setpoint pairing the AURATON R25 RT regulator with the RT receiver
allows for seng the temperature manually and controlling it in the locaon of the
fastening of the R25 RT regulator.
B) The remote setpoint if the T-2 thermometer is addionally paired with the RT receiver,
the AURATON R25 RT regulator retains the capability of temperature seng, however
its control is performed with the paired T-2 thermometer only. This feature allows for
regulang the temperature in a room other than the one where the AURATON R25 RT
regulator is placed.
An example: you want the temperature in the “children’s room” to be always at 22°C,
however you do not want children to be able to change it - in that room, you install the
T-2 thermometer, and the AURATON R25 RT regulator in e.g. the kitchen. This way the
temperature in the “children’s room” will always be at 22°C regardless of temperature
uctuaons in the kitchen.
C) The factory setpoint (20°C) if the T-2 thermometer is the only device paired with
the RT receiver, it is not possible to set the temperature manually, and the RT receiver
maintains the factory temperature setpoint of 20°C.
NOTE!
1. The sequence of pairing the AURATON R25 RT regulator and the T-2 thermometer
is very important. If you want to maintain the remote setpoint, you must rst pair
the AURATON R25 RT with the RT receiver, and then the T-2 thermometer. Reversing
the pairing sequence will cause automac deregistering of the previously paired T-2
thermometer and entering the mode of operaon described in item A.
2. The RT receiver can operate with one AURATON R25 RT regulator and/or one T-2
thermometer only. Pairing a new regulator causes deregistering the previously
paired regulator and the T-2 thermometer. Pairing a new T-2 thermometer causes
deregistering the previously paired T-2 thermometer only.
3. The R25 RT regulator and/or the T-2 thermometer can operate with an unlimited
number of receivers, e.g. one regulator can simultaneously control two independent
heang devices.