Questions and Answers

  • K
    kayla67Sep 8, 2025
    How to troubleshoot 'Solenoid is disconnected, shorted or stuck on' error on AutoAnchor Marine Equipment?
    • S
      Sarah FaulknerSep 8, 2025
      If your AutoAnchor Marine Equipment displays 'Solenoid is disconnected, shorted or stuck on', use another control to check if the solenoid is operating the windlass. To view the solenoid wiring readouts, go to Diagnostics in the Setup menu.
  • D
    Dana WattsSep 7, 2025
    What to do if AutoAnchor Marine Equipment shows 'Sensor: No sensor pulses detected'?
    • M
      Maria McdanielSep 7, 2025
      If the AutoAnchor Marine Equipment displays 'Sensor: No sensor pulses detected', it could be due to several reasons. First, use manual operation to verify that the windlass speed exceeds the minimum operating speed of 5 meters per minute. Next, confirm that the correct windlass setup and sensor have been selected. Then, inspect the magnet and sensor installation, checking for damage such as a rusted magnet. Ensure the gap between the magnet and sensor is correct for your setup. Finally, if using a rope/chain system, ensure the sensor installation is compatible with a rope/chain setup. The AA570 will still allow you to operate the windlass up and down in manual mode.
  • R
    Ryan ReyesAug 22, 2025
    Why is auto mode disabled on my AutoAnchor Remote Control?
    • E
      Eric BoydAug 22, 2025
      Auto mode is disabled on the AutoAnchor Remote Control when no sensor pulses are detected, the sensor installation isn't compatible with rope and chain settings, the load sensing wires aren't connected for rope/chain counting, a solenoid wire is disconnected, no rode to be released value has been entered, or total rode is set to OFF. When this message appears, the AA710 will operate the windlass in manual mode.
  • A
    aguilarcodySep 4, 2025
    Why does my AutoAnchor Marine Equipment display 'Motor externally controlled'?
    • R
      Rebecca RobinsonSep 4, 2025
      If your AutoAnchor Marine Equipment shows 'Motor externally controlled', it could be due to several reasons. Another control might be operating the windlass. It's also possible that the solenoid common ground is either not connected or is swapped with an up or down terminal. A large voltage potential difference between the AA710 Ground and Solenoid common ground could also be the cause. Check the control settings.
  • Y
    ystewartSep 3, 2025
    What to do if AutoAnchor Marine Equipment shows 'Power supply wired incorrectly'?
    • T
      Timothy PatrickSep 3, 2025
      If your AutoAnchor Marine Equipment displays 'Power supply wired incorrectly', it means the wiring diagram wasn't followed, causing power to backfeed from a source outside the control circuit. Consult the wiring diagram to correct this. A common mistake is powering the AA710 and deck switches from different sources.
  • S
    Sandra StoneSep 2, 2025
    Why is my AutoAnchor Marine Equipment showing a 'Battery voltage too low' message?
    • M
      Maria GrahamSep 2, 2025
      If the AutoAnchor Marine Equipment displays the message 'Battery voltage too low to operate windlass', it could be due to a few reasons. First, even if the battery seems fully charged, inspect the wiring for any poor connections. Second, ensure the cable meets the required specifications; an incorrectly sized cable can cause a voltage drop between the battery and the AutoAnchor. The voltage is displayed on the status bar.
  • E
    Erin RiveraAug 31, 2025
    How to resolve 'Sensor: Sensor tuning and tuning done' message on AutoAnchor 710-6?
    • K
      Katherine WilliamsAug 31, 2025
      1. The plug and play sensor detector is operating. Deploy the rode through the windlass until the message changes to “Tuning done” then dock the anchor. 2. If the “sensor tuning” message does not change to “tuning done” after 10 turns of the windlass, check the sensor installation is correct.
  • A
    Alice MartinAug 30, 2025
    How to troubleshoot 'Solenoid is disconnected, shorted or stuck on' on AutoAnchor 710-6?
    • S
      sbonillaAug 30, 2025
      The 'Solenoid is disconnected, shorted or stuck on' message on your AutoAnchor Remote Control can be resolved by: 1. Using another control to check if the solenoid is operating the windlass. 2. Going to Diagnostics in the Setup menu to view the solenoid wiring readouts. 3. Checking the solenoid wiring for open circuit or short circuit.
  • B
    Barbara CarrilloAug 29, 2025
    What to do if my AutoAnchor 710-6 shows 'Battery voltage too low to operate windlass'?
    • J
      James WalkerAug 29, 2025
      If your AutoAnchor Remote Control displays 'Battery voltage too low to operate windlass': 1. If the battery is fully charged, check the wiring for bad connections. 2. Check the cable meets the specifications.
  • S
    silvameredithAug 27, 2025
    What to do if AutoAnchor 710-6 Remote Control displays 'Sensor: Sensor installation not compatible with rope and chain settings'?
    • P
      Peter PriceAug 27, 2025
      The 'Sensor: Sensor installation not compatible with rope and chain settings' message on your AutoAnchor Remote Control can be resolved by: 1. Checking the correct windlass setup has been selected. 2. Checking the magnet and sensor installation is correct. 3. Checking that the load sensing wires are connected. 4. Going to Diagnostics in the Setup Menu to view sensor signal readouts.