Models FFG-10 and MTI-10
Operator's Manual
A Patented Product of
Motion Technology, Inc.
6 Huron Drive
Natick, MA 01760
Telephone: (508) 653-0082
Technical Support: 888-664-6640
MTI Form OP-0010 Rev. 005 5/98
E167653

Questions and Answers

  • B
    brennanjacobAug 7, 2025
    What to do if my AUTOFRY MTI-10 with RTD Fryer display is blank but the fan is on?
    • L
      Lisa WilsonAug 7, 2025
      If your AUTOFRY Fryer's display is blank while the fan is running, the issue might be an open safety. You should inspect all safeties, ensure the fan is working correctly, check the fire system gauge, and inspect the filter. Also, verify and adjust the airflow switch.
  • J
    Jennifer EllisAug 12, 2025
    What to do if my AUTOFRY MTI-10 with RTD Fryer heater fails to reach the set point in 16 minutes?
    • F
      fandersonAug 12, 2025
      If the heater in your AUTOFRY Fryer isn't reaching the set temperature within 16 minutes, you should check the supply voltage, the supply breaker, and the limit reset. Also, examine the voltage at the heater plug. As an additional step, you can unplug the fryer from the power supply or press the OFF button.
  • S
    Stephanie RubioAug 17, 2025
    What to do if my AUTOFRY MTI-10 with RTD shows a temperature difference of 50 degrees in 5 seconds?
    • S
      Stephen RoweAug 17, 2025
      If your AUTOFRY Fryer shows a temperature difference of 50 degrees in a 5-second period, verify the oil level and condition. You can also try unplugging the fryer from the wall to reset the board. Alternatively, press the OFF button and unplug the fryer from the supply.
  • L
    Leslie LunaAug 21, 2025
    How to resolve frequency conflict or thermocouple short in AUTOFRY Fryer?
    • J
      Joe MartinezAug 21, 2025
      To resolve a frequency conflict or thermocouple short in your AUTOFRY Fryer, start by checking the installation of the yellow thermocouple and the condition of the cord. Also, check the TC1 connections on the circuit board and the connections at the thermocouple socket in the heater box, ensuring that yellow is (+) and red is (-).
  • E
    Evan BoyleAug 27, 2025
    What to do if basket motor is not in position after 10 seconds in AUTOFRY MTI-10 with RTD Fryer?
    • S
      Sean MeyerAug 27, 2025
      If the basket motor in your AUTOFRY Fryer isn't in position after 10 seconds, check for broken gears, all wire connections, switches, and the tightness of the switch cam. As an additional step, you can unplug the fryer from the power supply or press the OFF button.
  • A
    Ashley HigginsSep 1, 2025
    How to check RTD or Thermocouple Probe in AUTOFRY MTI-10 with RTD Fryer?
    • Q
      qharrisSep 1, 2025
      To check the RTD or Thermocouple Probe in your AUTOFRY Fryer, inspect the plugs and sockets, and the probe itself. Also, check the condition of all cords and connections. See also A07.

Summary

AUTOFRY Specifications

FF6-10 Electrical Specs

Electrical requirements for the AUTOFRY FF6-10 model.

MTI-10 RTD Electrical Specs

Electrical requirements for the AUTOFRY MTI-10 model with RTD.

MTI-10 Thermocouple Electrical Specs

Electrical requirements for the AUTOFRY MTI-10 model with Thermocouple.

Initial Setup and Preparation

Prepare Electrical Service

Instructions for connecting electrical service to the AUTOFRY unit according to codes.

AUTOFRY Installation and Assembly

Connect Temperature Sensors and Heater

Connecting the RTD/Thermocouple and heater plugs to the heater box correctly.

Connect Power and Start Up

Connecting the AUTOFRY to power and turning it on for the first time.

Cooking Operations

Start Up and Preheat

Initial steps to power on and preheat the AUTOFRY unit before cooking.

Begin Cooking Cycle

How to enter cook times and start the cooking cycle for food products.

During Cooking Cycle

Understanding the stages of a cooking cycle, including basket movement and draining.

AUTOFRY Shutoff Procedure

Cleaning and Maintenance Guide

Fire Suppression System Inspection

Requirements for inspecting the fire suppression system every six months.

Safety System Testing

Procedures for testing the safety system, including airflow and interlock switches.

Airflow Switch Test Procedure

Detailed steps for testing the airflow switch by blocking exhaust flow.

Troubleshooting and FAQs

Error Code Diagnostics

A table detailing error codes, their conditions, diagnostics, and reset procedures.

AUTOFRY MTI-10 with RTD Specifications

General IconGeneral
BrandAUTOFRY
ModelMTI-10 with RTD
CategoryFryer
LanguageEnglish

Related product manuals