EasyManua.ls Logo

AUTOFRY FFG-10 - User Manual

AUTOFRY FFG-10
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Models FFG-10 and MTI-10
Operator's Manual
A Patented Product of
Motion Technology, Inc.
6 Huron Drive
Natick, MA 01760
Telephone: (508) 653-0082
Technical Support: 888-664-6640
MTI Form OP-0010 Rev. 005 5/98
E167653

Questions and Answers

  • S
    Stephanie TurnerAug 2, 2025
    What to do if my AUTOFRY Fryer display is blank but the fan is on?
    • K
      Kathleen ReynoldsAug 2, 2025
      If your AUTOFRY Fryer's display is blank while the fan is running, the issue might be an open safety. You should inspect all safeties, ensure the fan is working correctly, check the fire system gauge, and inspect the filter. Also, verify and adjust the airflow switch.
  • R
    Rachel RobbinsAug 7, 2025
    What to do if my AUTOFRY Fryer heater fails to reach the set point in 16 minutes?
    • A
      amy30Aug 7, 2025
      If the heater in your AUTOFRY Fryer isn't reaching the set temperature within 16 minutes, you should check the supply voltage, the supply breaker, and the limit reset. Also, examine the voltage at the heater plug. As an additional step, you can unplug the fryer from the power supply or press the OFF button.
  • J
    Joseph Cole PhDAug 12, 2025
    What to do if my AUTOFRY FFG-10 Fryer shows a temperature difference of 50 degrees in 5 seconds?
    • W
      William JacksonAug 12, 2025
      If your AUTOFRY Fryer shows a temperature difference of 50 degrees in a 5-second period, verify the oil level and condition. You can also try unplugging the fryer from the wall to reset the board. Alternatively, press the OFF button and unplug the fryer from the supply.
  • M
    Morgan HopkinsAug 16, 2025
    How to resolve frequency conflict or thermocouple short in AUTOFRY FFG-10 Fryer?
    • D
      davidbarajasAug 16, 2025
      To resolve a frequency conflict or thermocouple short in your AUTOFRY Fryer, start by checking the installation of the yellow thermocouple and the condition of the cord. Also, check the TC1 connections on the circuit board and the connections at the thermocouple socket in the heater box, ensuring that yellow is (+) and red is (-).
  • C
    Corey RobersonAug 21, 2025
    What to do if basket motor is not in position after 10 seconds in AUTOFRY Fryer?
    • G
      gregory30Aug 22, 2025
      If the basket motor in your AUTOFRY Fryer isn't in position after 10 seconds, check for broken gears, all wire connections, switches, and the tightness of the switch cam. As an additional step, you can unplug the fryer from the power supply or press the OFF button.
  • K
    khuffmanAug 27, 2025
    How to check RTD or Thermocouple Probe in AUTOFRY FFG-10?
    • M
      Mrs. Laura LaneAug 27, 2025
      To check the RTD or Thermocouple Probe in your AUTOFRY Fryer, inspect the plugs and sockets, and the probe itself. Also, check the condition of all cords and connections. See also A07.

Summary

Specifications

AUTOFRY Model FF6-10 Electrical Specifications

Details electrical requirements for the FF6-10 model, including voltage, wattage, and plug type.

AUTOFRY Model MTI-10 with RTD Electrical Specs

Outlines electrical requirements for MTI-10 models equipped with RTD, covering voltage and amperage.

AUTOFRY Model MTI-10 with Thermocouple Electrical Specs

Specifies electrical requirements for MTI-10 models with thermocouple, including voltage and amperage.

AUTOFRY Setup and Installation

Prepare Electrical Service

Instructions for connecting the unit to a proper electrical supply according to codes.

Prepare Counter Top

Guidance on selecting a suitable, level, and fire-resistant location for the unit.

AUTOFRY Installation

Charcoal Filter Removal and Leg Installation

Instructions for installing the unit's legs and removing the charcoal filter.

Initial Cleaning Procedure

Steps for washing and cleaning unit components before first use.

Cooking Operations

Starting the AUTOFRY

Guide to initiating the heating process, monitoring temperature, and test cycles.

Begin Cooking Procedure

Step-by-step instructions for entering cook times and starting a cooking cycle.

During Cooking Cycle

Explains the process, indicators, and cycles during an active cooking operation.

AUTOFRY Shutoff Procedure

Programming Cook Times

Recommended Cleaning Schedule

Daily Cleaning Procedures

Step-by-step guide for daily cleaning tasks, including washing and drying components.

Weekly Cleaning

Quarterly Cleaning and Maintenance

Filter Maintenance

Charcoal Filter Replacement

Procedure for replacing the charcoal filter medium, including cleaning housing.

Second Filter Replacement

Guidelines for replacing or cleaning the secondary filter.

Semi-Annual Safety Checks

Fire Suppression System Inspection

Requirements for inspecting the fire suppression system according to safety standards.

Safety System Test Procedure

Steps for performing the safety system test to ensure proper function.

Error Codes and Diagnostics

AUTOFRY FFG-10 Specifications

General IconGeneral
BrandAUTOFRY
ModelFFG-10
CategoryFryer
LanguageEnglish