AUTOFRY Models FFG-10 and MTI-10 Operator's Manual
Error Codes
EPROM DIAGNOSTICS
plug from supply or press
cords and connections, (see
417
213
A02
Prb
Check all safeties, check fan
operation, check fire system
Check for broken gears, check
all wire connections, check
plug from supply or press
A04
A04
switches, check switch cam
Check supply voltage, check
supply breaker, check limit re
plug from supply or press
set, check voltage at heater
N/A N/A N/A A06 Call Customer Service Call Customer Service Press OFF
Check yellow thermocouple
condition. Check connections
TC1 on circuit board. Check
connections at thermocouple
socket in heater box (yellow
A08
Temperature difference
of 50 Deg. In 5 second
Check oil level. Check oil
condition. Un-plug from wall
Press OFF and Un-plug from
supply
NOTE: AO errors should not be confused with cook times. Error codes do not use a colon cook
times do. The NCC controller can display cook times of
MTI FormOP-0010 Rev. 005 5/98
E167654