AUTOFRY Models FFG-10 and MTI-10 Operator's Manual
Add liquid shortening (2.5- 2.75 Gallons).
Making certain that the drain valve is in the closed position (see Figure
6) add liquid shortening to the oil pot. Ensure that the oil level is
approximately 1/2" - 3/4" below the fill line stamped on the interior of the
oil pot.
It is simpler and safer to add cool shortening to the oil pot than it is to remove
hot shortening. Once the AUTOFRY has heated the shortening will expand.
Only after this expansion has finished should the oil level be increased to the
FILL level.
Over filling will result in excessive splashing; never over fill the oil pot.
Under-filling the oil pot will result in under-cooked food product or poor
and erratic temperature readings. Extreme low oil levels could cause
smoking.
NEVER operate the AUTOFRY in a low or no oil condition
Install the food exit chute.