AUTOFRY Models FFG-10 and MTI-10 operator's Manual
Charcoal Filter
VERY IMPORTANT In order for the AUTOFRY to continue to perform as a
ventless cooking appliance the charcoal filter medium or
activated charcoal must be changed a minimum of every three months. This
maintenance is required by your equipment warranty.
While replacing the charcoal medium is easy, there will be some charcoal dust
present. Replacing the charcoal medium should be performed away from your food
preparation areas.
Remove the charcoal filter.
Remove the four screws holding the perforated cover.
Pour the used charcoal into a suitable container.
Clean the re-usable housing and perforated screen to bare metal
in warm soapy water followed by a clear water rinse.
Thoroughly dry the housing and cover.
Pour the new charcoal into the housing and re-seat the cover and
screws.
Replace the charcoal filter and all the filter components.
All activated carbons do not have the same performance
characteristics. Use replacement charcoal supplied by AUTOFRY
which can be ordered by calling 1-800-348-2976.
Second Filter
The second filter must be replaced a minimum of once every 6 months. Heavy
usage may require that the second filter be changed more frequently; however, if
it appears the second filter can no longer be cleaned effectively then it should be
replaced!
Second filters can be ordered by calling 1-800-348-2976.