AUTOFRY Models FFG-10 and MTI-10 Operator's Manual
Install Charcoal Filter
Remove the filter cover plate from the back interior wall of the cooking
chamber by removing the two black plastic knobs securing the cover
plate (see Figure 4).
Remove the charcoal filter from the plastic bag with the flange facing
down and facing you insert it into the tracks above the second filter (see
Figure 5).
Re-install the filter cover plate by turning the black plastic knobs
clockwise to a hand tight fit. Verify that the word "TOP" on the filter cover
plate is in the upper left-hand corner (see Figure 4).
Both the grease baffle and the second filter have small holes along the one
side of the frame. These drain holes must be facing down in order for the filters to
efficiently drain and clean the air (see Figure 5).
Sanitize interior.
All interior surfaces must be sanitized in a quaternary ammonia or iodine
solution at a temperature of at least 75° F following the manufacturer's label
instructions.