AUTOFRY Models FFG-10 and MTI-10 Operator's Manual
The Stand-By Button
The Button is used during off peak hours to conserve energy and
maximize oil life.
To Activate Stand-By Mode
For all AUTOFRY models, press the
button and the 0 STAND BY
light will illuminate.
The heating element shuts off until the oil temperature drops below 300° F and
then maintains this temperature.
To Exit Stand-By Mode
? For the AUTOFRY with an RTD
Press the button.
? For the AUTOFRY with a thermocouple
Press the CLEAR button
The 0 STAND BY light will go out and the oil will begin to heat up until it reaches
the ready temperature.
Never shut off the AUTOFRY while in the Stand-By mode as the keypad may remain
locked in the Stand-By mode! If this should happen when you
re-start the AUTOFRY simply press the key a second time or press the
CLEAR button.
Repeat Cook Time
Use the following procedure to repeat the last entered cook time:
Simply press the START and your last cook time will be repeated.
This may be useful if you have a single product menu or multi-product menu
with identical cook times.
Maximum Cook Time
The AUTOFRY equipped with the RTD has a maximum cook time of 10 minutes
and 49 seconds.
The AUTOFRY equipped with thermocouple has maximum cook time of 15 minute
and 59 seconds.
MTI FormOP-0010 Rev. 005 5/98 15