EasyManua.ls Logo

AUTOFRY FFG-10 - Weekly Cleaning; Repeat Daily Cleaning Tasks; Remove Heater Box Assembly; Remove and Clean Oil Pot

AUTOFRY FFG-10
34 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AUTOFRY Models FFG-10 and MTI-10 Operator's Manual
Weekly Cleaning
Repeat daily cleaning.
Remove the heater box assembly.
Never immerse the heater box. Permanent damage will
result. Use caution when cleaning around the
temperature probes.
Remove the oil pot.
? Discard the oil or shortening in an environmentally safe manner.
Clean all surfaces to bare metal
Re-apply a thin even coating of Kote ® brand soil shield to the exterior
surfaces of the oil pot.
Clean all interior surfaces to bare metal
Use extreme caution when cleaning around the fire
system actuation cables and fusable link in the
interior cabinet. Accidental discharge of the fire
system could result, (see figures 12A & 12B).
Sanitize all part and interior surfaces in a quaternary ammonia or iodine
solution at a room temperature of at least 75° F following the manufacturer's
label instructions.
MTI FormOP-0010 Rev. 005 5/98
E167654
21

Related product manuals