9
OPERATIONS INSTRUCTION
Install the hook onto the hook port (E) and hang under the
hood.
Open the filling cap and drain 10ml of test liquid into the filling
port (A).
If the smoke oil is overfilled, turn the unit upside down to drain
some oil out.
Preparation
before use
Smoke test
NOTE
Red clamp to positive (+), black clamp to negative (-). For best
performance, the vehicle battery shall be fully charged.
Only 12V vehicle battery is allowed to be used as power supply
for the unit.
NOTE
Mount the smoke hose to the smoke outlet (J) and the power
cord to the power socket (I).
Connect the power cord to 12V vehicle battery.
When the power indicator light (F) is on, there is air pressure
output from the nozzle on the smoke outlet tube.
Press the smoke control switch (H), and the work indicator light
(G) will illuminate, causing smoke to be emitted from the nozzle
on the smoke outlet tube. At this point, the main unit enters a
5-minute working cycle (after 5 minutes, the main unit will
automatically stop generating smoke). During the 5-minute
working cycle, pressing the smoke control switch (H) again will
immediately exit the working cycle and stop the smoke genera-
tion.
Start using the SDT203 after the first two steps.