Lostcommunicationbetweenthepower
centerandthegeneratorcell
Checkthecellcordconnectionatthepowercenterfordamagetothewire.
2.Transformerwiringisincorrect,checkitiswiredproperlyforincoming
voltage.
3.Fuse(10A)mayhavefailed,testandreplaceifnecessary.
4.TransformerorPower
Centercircuitboardhasfailed,repla cethePower
Center.(p/n:ECP0312)
AddSalttoachieve3,500ppm(mg/L).LoSALt
1.NopowertothePowerCenter,checkbreaker.Ifunitiswiredtoatime
clock,makesureitisturnedon.
NoDisplayNoDisplay/BlankDisplay
Alternating:
Output/24hr.
countdown
AlternatingDisplay
Normaloperation,unitisinBOOSTmode.PressandholdboththeUp
ArrowandDownArrowsimutaneouslytoactivate/deactivateBOOST
MODE.
DISPLAYMESSAGES&TROUBLESHOOTING
Problem
OPEnCELLErr Cellbladesarereceivingnocurrent Checkforlooseordamagedwiring,inspectcellfordamage.
NOFLO Insufficientwaterflow
1.Checkpumpforproperoperationandserviceasnecessary.
2.Checkfilter:clean/serviceasnecessary.
3.Checksystemvalvesettingsforproperflowtotheunit.
4.Checkfor
obstructioninthecell(d ebrisorscalingaccumulation).
5.Flowsensormayneedtobeservicedorreplaced. ContactalocalService
Centerforassistance.
CLnCELL Cellmaybescaled
Highvoltsaregoingtothecell.Checkcellforscale,cleanasnecessaryand
balancewater.
AddSALt
Solution
Saltlevelis
2,300‐2,700ppm(mg/L)
Saltlevelisbelow2,300ppm(mg/L) AddSalttoachieve3,500ppm(mg/L).
CLnCELLSOOn Thevoltageatthecellis26to28VDC.
Chlorineisstillbeinggenerated.Thecellmaybedirtyorhavecalcium
buildup.Inspectandcleanthecellasneeded.
HIgH
CurrErr
HighVoltageorOverCurrenthasbeen
detectedandthesystemislocked.
Possibleundissolvedsaltbrushedintothemaindrain.Thesaltwillneedto
dissolveforthisconditiontonormalize.Thesystemwillautomatically
recheckinonehourincrementstoseeifthisconditionpersists.Ifthe
condition
persists,thesystemwilllockwithahighcurrenterrorfault.A
powerresetwillberequiredtoclearthisfault.
SEnSErr
Atemperaturesensorerrorhasbeen
detected.
ContactalocalServiceCenterforassistance.
SHrtCELLErr
Lowvoltageorashortcircuithasbeen
detected.
Chlorinegen e rationis
halted.Ifthevoltageremainslow,thesystemwill
automaticallyretestfor1hour.Iftheissuepersists,contactalocalService
Centerforassistance.
RS485Data(+)‐ TerminalA
RS485Data()‐ TerminalB
Black wirefromPoolSync® toGND
YellowwirefromPoolSync®toA
GreenwirefromPoolSync®toB
RedwirefromPoolSync®toVDC
PoolcoverSwitch
(drycontacts)
RS485Data(+)‐ TerminalA
RS485Data()‐ TerminalB
Connectonlyonered
wireforPoolSync.If
usingPoolSyncon
additionaldevices,
leaveredwireoffon
thoseadditional
devices.
LTM1034
2of2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Autopilot ChlorSync and is the answer not in the manual?

Autopilot ChlorSync Specifications

General IconGeneral
BrandAutopilot
ModelChlorSync
CategorySwimming Pool Filter
LanguageEnglish

Related product manuals