The 460i Electronic Control System
Operation and Maintenance Manual
460i

Questions and Answers

  • T
    Timothy StewartAug 20, 2025
    Why Autotrol 460i Control Systems will not regenerate automatically or when button is pressed?
    • C
      Cathy MerrittAug 20, 2025
      If your Autotrol Control Systems won't regenerate automatically or when the button is pressed, check the following: * Make sure the electric cord is plugged in and connected to a working outlet. * A defective motor, broken gear, binding in the gear train, or defective switch could be the cause. In any of these cases, the timer should be replaced.
  • J
    Jennifer FosterAug 22, 2025
    What to do if Autotrol 460i Control Systems timer is stalled in regeneration cycle?
    • J
      Julie NicholsAug 22, 2025
      If the Autotrol Control Systems timer is stalled in the regeneration cycle, here are some things to check: 1. **Power:** Ensure the unit is plugged into a working outlet. 2. **Timer components:** Issues like a dead motor, a motor running backwards, a broken gear, or a defective switch all require replacing the timer. 3. **Other issues:** Check for air leaks in brine connections, binding of the camshaft, or water pressure exceeding 125 psi during regeneration (install a pressure regulator if needed). 4. **Defective circuit board:** Replace the timer.
  • H
    hernandezedwardAug 25, 2025
    Why Autotrol 460i will not regenerate automatically but will regenerate when button is pressed?
    • M
      Melissa SimpsonAug 26, 2025
      If Autotrol Control Systems will not regenerate automatically but will regenerate when button is pressed, it could be due to: * A water flow display that is not working. Refer to troubleshooting for the 'No water flow display' issue. * A defective circuit board. In this case, replace the timer. * Incorrect hardness and capacity settings. Set to correct values.
  • J
    Jennifer FoxAug 28, 2025
    Why does my Autotrol 460i regenerate at the wrong time of day?
    • A
      Ashley LewisAug 28, 2025
      If your Autotrol Control Systems regenerates at the wrong time of day, it's likely due to: * Power outages: Reset the clock to the correct time of day. * Incorrect clock settings: Reset the clock to the correct time of day.
  • B
    Brooke AlexanderAug 31, 2025
    Why Autotrol 460i Control Systems clock does not display correct time of day?
    • C
      Cindy ClarkAug 31, 2025
      If the clock on your Autotrol Control Systems does not display the correct time of day: * Ensure the outlet is not controlled by a switch. Use an outlet that is always on. * Incorrect voltage or frequency (Hz) can cause time display issues. Replace the timer with one of the correct voltage and frequency (Hz). * After power outages, reset the clock.
  • J
    James SandovalSep 2, 2025
    What to do if there is no water flow display when water is flowing with Autotrol Control Systems?
    • L
      Laura CarterSep 2, 2025
      If there is no water flow display when water is flowing in your Autotrol Control Systems, consider these potential causes: * Ensure the bypass valve is not in the bypass position. * Check that the meter probe is fully inserted into the meter housing. * Remove any foreign material that may be restricting the meter turbine's rotation, and flush with clean water. If the turbine doesn't spin freely, replace the meter. * A defective meter probe or circuit board may be the cause. In any of these cases, the timer should be replaced.
  • R
    Rachel McdanielSep 5, 2025
    What to do if Autotrol 460i Control Systems time display shows something other than time of day?
    • J
      jeannekingSep 5, 2025
      If the time display on your Autotrol Control Systems shows something other than the time of day, it could be due to electrical interference or a defective circuit board. Try disconnecting power to the unit, then restore power and reset the time of day display. If the problem persists, replace the timer.
  • C
    Christopher ThompsonSep 8, 2025
    How to fix Autotrol Control Systems clock that does not display time of day?
    • C
      cookcoreySep 8, 2025
      If the clock on your Autotrol Control Systems isn't showing the time of day, here's what to check: * **Power cord:** Make sure the transformer cord is plugged in. * **Outlet:** Verify the outlet has power; if not, repair it or use a working outlet. * **Transformer:** If the transformer is defective, it will need to be replaced. * **Circuit board:** A defective circuit board will require replacing the timer.
  • K
    Kayla MezaSep 12, 2025
    Why Autotrol Control Systems camshaft does not stop at the end of regeneration?
    • S
      Sheila DeleonSep 12, 2025
      If your Autotrol Control Systems is in continuous regeneration and the camshaft doesn't stop, it's likely due to a broken switch activator on the gear or a defective switch. In either case, the timer should be replaced.
  • B
    Bradley CollinsSep 13, 2025
    Why does the time display continue to advance on my Autotrol 460i Control Systems?
    • C
      Carrie KramerSep 13, 2025
      If the time display on your Autotrol Control Systems continues to advance, it indicates a defective time set switch. The solution is to replace the timer.

Summary

460 i Electronic Demand System

Memory Retention

Stores data in NOVRAM during power outages, resuming operation seamlessly.

Self-Adjusting Reserve

Microprocessor adjusts soft water reserve based on average usage for optimum economy.

Programming the 460 i

Time of Day Setting

Set the current time of day using the TIME SET BUTTON for accurate regeneration scheduling.

Hardness Setting

Adjust the water hardness setting for proper water treatment and regeneration.

Capacity Setting

Set the system's capacity to match water needs for optimal performance.

Adjustment of Brine Control

Troubleshooting

Failure to Regenerate

Diagnoses why the unit fails to initiate regeneration automatically or manually.

Soft Water Depletion

Solves issues leading to a lack of soft water between scheduled regeneration cycles.