Questions and Answers

  • T
    traceymartinAug 20, 2025
    Why does my Autotrol Performa 440i Control Control Systems timer not display the correct time?
    • N
      Nancy BellAug 20, 2025
      If the Autotrol Control Systems timer does not display the correct time of day, ensure the outlet is not controlled by a switch. If power outages occur, reset the time of day.
  • E
    Eric SantiagoAug 25, 2025
    Why Autotrol Control Systems control does not regenerate automatically?
    • B
      Brenda HortonAug 25, 2025
      If your Autotrol Control Systems control will not regenerate automatically, ensure the transformer is plugged in and that there is electric power at the outlet. If these are not the cause, the motor, gear, gear train, or switch may be defective, in which case the control needs to be replaced.
  • S
    Stacie LeeAug 27, 2025
    How to fix Autotrol Performa 440i Control Control Systems that regenerates at wrong time of day?
    • A
      Austin StewartAug 27, 2025
      If the Autotrol Control Systems control regenerates at the wrong time of day, reset the time of day and regeneration to the correct settings. This could be due to power outages or incorrect time settings.
  • B
    brianaholmesAug 28, 2025
    How to fix Err 2 on Autotrol Performa 440i Control?
    • G
      Gerald LopezAug 28, 2025
      To resolve Err 2 on your Autotrol Control Systems, press any key to silence the alarm. The control will then turn the motor on and drive the camshaft to the proper location. If the valve camshaft has been manually rotated out of the 'regeneration complete' position, or if there is a faulty motor, motor drive or switch, replace the control.
  • K
    Kelly MayAug 30, 2025
    What to do if Autotrol Performa 440i Control Control Systems shows Err 3?
    • L
      lauren89Aug 30, 2025
      To resolve Err 3 on your Autotrol Control Systems, the control will turn the motor on and drive the camshaft to the proper location. If the error persists, it may be due to a faulty motor, motor drive, or switch, in which case you should replace the control.
  • J
    jhuntSep 1, 2025
    How to solve Err 4 on Autotrol Performa 440i Control?
    • T
      Tina SmithSep 1, 2025
      To fix Err 4 on your Autotrol Control Systems, adjust the settings that are out of the allowable range. Hardness should be between 3 and 250, capacity between 0.1 and 140.0, refill control between 1 and 99, and brine draw value according to Table 2.
  • M
    Martin LopezSep 3, 2025
    Why Autotrol Control Systems control regenerates only when REGEN button is depressed?
    • K
      Kelli Mcdonald DDSSep 3, 2025
      If your Autotrol Control Systems control does not regenerate automatically but does regenerate when the REGEN button is depressed, refer to item 5 in this table if the water flow display is not operative. Otherwise, set new control values and refer to the Programming section, or replace the control if the circuit board is defective.
  • A
    Audrey HubbardSep 5, 2025
    What does Err 1 mean on Autotrol Control Systems?
    • E
      Emily LopezSep 5, 2025
      To resolve Err 1 on your Autotrol Control Systems, press any key to load default values. Then, refer to the 'Programming the Model 960 Control' section for further instructions.
  • A
    Andrew ReedSep 7, 2025
    Why does Autotrol Control Systems timer not display time of day?
    • L
      Laura SimpsonSep 7, 2025
      If the Autotrol Control Systems timer does not display the time of day, connect the transformer to power or repair the outlet if there is no electric power. If the issue persists, the transformer or circuit board may be defective, requiring replacement of the transformer or the entire control.
  • K
    Kenneth GallagherSep 9, 2025
    What to do if Autotrol Performa 440i Control Control Systems runs out of treated water between regenerations?
    • N
      natalieortizSep 9, 2025
      If you run out of treated water between regenerations with your Autotrol Control Systems, repeat regeneration ensuring the correct salt dosage is used. Other causes may include a fouled resin bed (use resin cleaner), incorrect factor 1 or capacity settings (set to correct values), restricted meter turbine rotation due to foreign material in the meter housing (remove meter housing, free up turbine, and flush with clean water; replace meter if turbine does not spin freely), or excessive water usage below 1/5 gallon per minute (repair leaky plumbing and/or fixtures).

Summary

Installation and Setup

Location Selection for Water Conditioner

Choosing an optimal location for the water conditioner unit, considering distance to drain and water heater.

Water Line Connection Procedure

Connecting the water supply to the conditioner, recommending a bypass valve system.

Drain Line Connection Guidelines

Guidelines for connecting the drain line, including tubing size and elevation.

Placing Conditioner into Operation

Step-by-step process to put the water conditioner into service after installation.

Electrical Connection for Controls

Instructions for connecting the control unit to the electrical power source.

Control Settings and Programming

Regeneration Cycles Management

Automatic Regeneration Triggers

Methods for automatic regeneration: calendar override or metered usage.

Servicing and Maintenance Procedures

Removing Valve Assembly for Servicing

General steps to remove the valve assembly from the tank.

Removing 440 i Control for Servicing

Step-by-step guide to safely remove the 440i control unit.

Removing 940 F and 960 F Controls for Servicing

Step-by-step guide to safely remove the 940F and 960F control units.

Troubleshooting Common Issues

Valve Troubleshooting

Common problems and solutions for the control valve itself.

440 i & 940 F Control Troubleshooting

Specific issues and fixes for 440i and 940F control units.

960 F Control Troubleshooting

Specific issues and fixes for the 960F control unit.

960 F Control Alarms

Explains alarm indications, causes, and solutions for the 960F control.

960 Control Common Problems

Lists common problems and solutions for the 960 control system.

960 Control Common Problems (Continued)

Additional common problems and solutions for the 960 control system.

Autotrol Performa 440i Control Specifications

General IconGeneral
ModelPerforma 440i
Operating Pressure20-125 PSI
Operating Temperature34 - 120°F (1 - 49°C)
DisplayLCD
MountingTank Mounted
CompatibilityWater Softeners, Filters