Installation, Operation and Maintenance Manual
Autotrol Performa Filter Valve Series
®
TM

Questions and Answers

  • M
    Mrs. Kiara BrowningSep 12, 2025
    Why no water flow display when water is flowing on Autotrol Control Systems?
    • D
      Daniel Peterson Jr.Sep 12, 2025
      If there is no water flow display when water is flowing in your Autotrol Control Systems (colon does not blink), shift the bypass valve into the service position. Also, ensure the meter probe is fully inserted into the meter housing. If the meter turbine rotation is restricted due to foreign material, remove the meter housing, free up the turbine, and flush with clean water. If the turbine does not spin freely, refer to the Water Meter Maintenance section. If the problem persists, the meter probe or circuit board may be defective, requiring replacement of the control.
  • B
    Brittany HebertSep 13, 2025
    Why Autotrol Performa 440i Control control backwashes at excessively low or high rate?
    • K
      Kevin RobinsonSep 13, 2025
      If the Autotrol Control Systems control backwashes at an excessively low or high rate, it may be due to an incorrect backwash controller being used (replace with the correct size controller) or foreign matter affecting the controller operation (remove the controller and ball, then flush with water).
  • K
    kirwinSep 15, 2025
    What to do if Autotrol Control Systems has untreated water leakage during service?
    • A
      Angela Perez DVMSep 15, 2025
      If you experience untreated water leakage during service with your Autotrol Control Systems, repeat regeneration making certain that the correct salt dosage is set. If the bypass valve is leaking, replace the O-ring. If the O-ring around the riser tube is damaged, replace the O-ring.
  • M
    Michael KaneSep 17, 2025
    Why Autotrol Performa 440i Control Control Systems control will not regenerate automatically?
    • B
      Benjamin EscobarSep 17, 2025
      If your Autotrol Control Systems control will not regenerate automatically, connect the power if the transformer or motor is not connected. If the timer motor is defective, replace it. Ensure the skipper pins are down on the timer skipper wheel for the days regeneration is required. If there is binding in the gear train of the timer, replace the timer.
  • A
    Adam LangNov 21, 2025
    What to do if Autotrol Performa 440i Control timer stalled in regeneration cycle?
    • B
      Brian BurnettNov 21, 2025
      If your Autotrol Control Systems timer is stalled in the regeneration cycle, several issues could be the cause. It could be due to the motor not operating or running backwards, in which case you should replace the control. Other potential causes include no electric power at the outlet (repair the outlet or use a working one), incorrect voltage or frequency (replace the timer and/or transformer with the correct one), a broken gear, or a defective switch (in all of these cases, replace the control). An air leak in brine connections or binding of the camshaft can also cause this issue; check all junction points and remove any obstructions from the valve discs or camshaft, respectively. High water pressure during regeneration or a defective circuit board can also be the reason; install a press...

Summary

Installation and Setup

Location Selection for Water Conditioner

Choosing an optimal location for the water conditioner unit, considering distance to drain and water heater.

Water Line Connection Procedure

Connecting the water supply to the conditioner, recommending a bypass valve system.

Drain Line Connection Guidelines

Guidelines for connecting the drain line, including tubing size and elevation.

Placing Conditioner into Operation

Step-by-step process to put the water conditioner into service after installation.

Electrical Connection for Controls

Instructions for connecting the control unit to the electrical power source.

Control Settings and Programming

Regeneration Cycles Management

Automatic Regeneration Triggers

Methods for automatic regeneration: calendar override or metered usage.

Servicing and Maintenance Procedures

Removing Valve Assembly for Servicing

General steps to remove the valve assembly from the tank.

Removing 440 i Control for Servicing

Step-by-step guide to safely remove the 440i control unit.

Removing 940 F and 960 F Controls for Servicing

Step-by-step guide to safely remove the 940F and 960F control units.

Troubleshooting Common Issues

Valve Troubleshooting

Common problems and solutions for the control valve itself.

440 i & 940 F Control Troubleshooting

Specific issues and fixes for 440i and 940F control units.

960 F Control Troubleshooting

Specific issues and fixes for the 960F control unit.

960 F Control Alarms

Explains alarm indications, causes, and solutions for the 960F control.

960 Control Common Problems

Lists common problems and solutions for the 960 control system.

960 Control Common Problems (Continued)

Additional common problems and solutions for the 960 control system.

Autotrol Performa 440i Control Specifications

General IconGeneral
ModelPerforma 440i
Operating Pressure20-125 PSI
Operating Temperature34 - 120°F (1 - 49°C)
DisplayLCD
MountingTank Mounted
CompatibilityWater Softeners, Filters