400 Series Control Settings
440i Control
Figure 4
Programming
1. Set days of regeneration on skipper wheel (Figure 4).
Pull all skipper pins outward (away from
control).
Rotate skipper wheel until day arrow points to
current day or number 1.
Depress skipper pin(s) at day(s) for which
regeneration is desired.
2. Set the time of day.
Grasp timer knob and pull outward.
Rotate in either direction until the timer arrow
points to the actual time of day.
Release timer knob.
Note: with the time of day properly set, the conditioner
will regenerate at about 2:30 a.m. If you prefer to have
the unit regenerate at an earlier or later time, simply set
current time-of-day accordingly (e.g., to have the unit
regenerate at 4:30 a.m. - two hours later - set the clock
two hours earlier than the actual time of day.)
Note: The timer locking pin should always be horizontal
(Figure 4) during operation.
Guest Cycle
When abnormally high water usage exhausts your
water conditioner’s capacity ahead of schedule, an
extra regeneration can be achieved. Depress the
indicator knob on the 440i (Figure 4) with a wide-blade
screwdriver and turn COUNTERCLOCKWISE to
START to initiate a regeneration. It will take a few
minutes for regeneration to start. A normal regeneration
will take approximately two hours.
Manual Regeneration
Electricity is used only to run the control and to rotate
the camshaft. All other functions are operated by water
pressure. Therefore, in the event of a power outage, all
the regeneration positions may be dialed manually by
depressing the indicator knob and turning
COUNTERCLOCKWISE (Figure 4). The following
cycle times should be used for proper regeneration:
BACKWASH - 20 minutes
FAST RINSE - 10 minutes
900 ProSeries Control Settings
940F Control
Figure 5
Programming
1. Set days of regeneration (Figure 5).
Pull all day pins outward (away from control).
Depress day pin(s) for which regeneration is
desired.
Note: The NEXT DAY day pin is noted on the timer
face. Depressing this pin will insure a regeneration the
next day at approximately 2:00 a.m. Since the calendar
cap progresses CLOCKWISE, depressing the day pin
immediately COUNTERCLOCKWISE will insure a
regeneration the following day at 2:00 a.m. This
progression is noted on the timer face as “FUTURE
DAYS”.
Day Arrow
Skipper Pins
Skipper Wheels
Indicator Knob
Timer Locking Pin
Time Arrow
Timer Knob
F
A
S
T
R
I
N
S
E
B
A
C
K
W
A
S
H
S
E
R
V
I
C
E
FOR MANUAL
BACKWASH
ROTATE POINTER
COUNTER
CLOCKWISE TO
START POSITION
TO ADJUST BACKWASH
MINUTES, ROTATE
SMALL DIAL COUNTER
CLOCKWISE.
DO NOT ADJUST
DURING BACKWASH
TO SET
REGENERATION
DAYS PRESS PINS IN
Performa Filter
TM
BACKWASH COMPLETE
Indicator Knob
Clock Dial
Day Pins