6
2. Set the time of day.
• Rotate Clock Dial CLOCKWISE until the pointer
is directed at the current time.
Note: With the time of day properly set, the conditioner
will regenerate at about 2:00 a.m. If you prefer to have
the unit regenerate at an earlier or later time, simply set
the current time-of-day accordingly (e.g., to have the
unit REGENERATE at 4:00 a.m. - two hours later - set
the clock two hours earlier than the actual current time).
Note: Do not rotate the Calendar Cap by hand; the
clock dial indexes it daily. To manually index the
Calendar Cap, rotate the Clock Dial CLOCKWISE one
complete turn for every day to be indexed.
Figure 6
How to Adjust the Backwash Time
With the indicator knob in the BACKWASH COMPLETE
position (Figure 6), rotate the Backwash Dial
COUNTERCLOCKWISE at least one full turn to cancel
the previous setting. A light clicking will be replaced by
a heavier clicking when the previous setting is
cancelled. Then, rotate the Backwash Dial to the
desired backwash time. The numbers are minutes of
backwash per regeneration.
Manual Regeneration
Electricity is used only to run the control and to rotate
the camshaft. All other functions are operated by water
pressure. Therefore, in the event of a power outage, all
regeneration positions may be dialed manually. Grasp
the indicator knob and turn COUNTERCLOCKWISE to
each regeneration cycle (rotation is much easier if you
grasp the camshaft with your free hand and turn it at
the same time). The following cycle times should be
used for proper regeneration.
BACKWASH - 20 minutes
FAST RINSE - 10 minutes
960F Control
Figure 7
Programming
This section covers all aspects of programming the
control. The control is shipped from the factory with
default values for most parameters. These default
values will result in a system capacity of 100 gallons
(1 cubic meter). While the control may operate with
these values, the following parameters must be
changed to meet the actual operating conditions:
Refill Controller Value, Brine Draw Rate, and Slow Rinse
Time parameters are not required for 960F operation,
but should be adjusted as instructed to achieve the
shortest possible backwash cycle time.
Note that some parameters have a single unit of
measure option. Other parameters have dual units
such as Capacity which can be entered in gallons or
cubic meters. To select which units are active, look for
a comment in the NOTES column of Tables 1 and 2. It
will reference another parameter that selects which
units are active. For example, parameter P12 (Table 2)
selects U.S. units if it is set to “0” and metric if it is set
to “1”.
Backwash Dial
Indicator Knob
Time of Day
Time of Regen
Factor A
Factor B
Capacity
Regen Time
Remaining
R
E
G
E
N
E
R
A
T
IO
N
C
O
M
P
L
E
T
E
F
A
S
T
R
I
N
S
E
B
A
C
K
W
A
S
H
P
M
Performa
Filter
TM
Cycle Indicator