AUX DC Inverter Free Match 50HZ R32
2.3 F Series (07K,09K)
Model
Indoor
Unit
AMWM-H07/4R3(F*)
AMWM-H09/4R3(F*)
Capacity
Cooling
Btu/h
7165(3855-9220)
9000(4780-11260)
kW
2.05(1.13-2.70)
2.58(1.40-3.30)
Heating
Btu/h
7510(3340-8530)
9215(4095-10240)
kW
2.15(0.98-2.50)
2.70(1.20-3.00)
Electric Data
Power Supply
V~,Hz,
Ph
220240,50,1
220240,50,1
Cooling Power Input
W
40(1268)
40(1268)
Heating Power Input
W
40(1268)
40(1268)
Indoor
Fan Motor
Model
/
YYK12-4B
YYK12-4B
Output Power
W
12
12
Speed (H/M/L)
r/min
1150
1150
Indoor Coil
a. Number Of Row
/
2
2
b.Tube Pitch(a)x Row
Pitch(b)
mm
20.5x 12.7
20.5x 12.7
c.Fin Pitch
mm
1.3
1.3
d.Fin Material
/
Hydrophilic aluminum fin
e.Tube Outside Dia.And
Material
mm
φ7 Inner grooved
Performance
Air Flow Volume
m
3
/h
600
600
Sound Pressure Noise
Level
dB(A)
51
54
Dimension
Net Dimension (W*D*H)
mm
750×285×200
750×285×200
Packing Dimension
(W*D*H)
mm
820×347×277
820×347×277
Weight
Net
kg
7.5
7.5
Gross
kg
9
9
Refrigerant Type
/
R32
R32
Pipe Diameter
Liquid Side
mm
(inch)
6.35(1/4)
6.35(1/4)
Gas Side
mm
(inch)
9.52(3/8)
9.52(3/8)
Drainage
mm
16.5
16.5
Loading Qty
20/40/40H
unit
384/768/864
384/768/864