Explains the model nomenclature for indoor and outdoor units.
Shows visual representations of different indoor and outdoor unit types.
Details features, specifications, dimensions, wiring, installation, and exploded views for this unit type.
Details features, specifications, dimensions, wiring, installation, and exploded views for this unit type.
Details features, specifications, dimensions, wiring, fan performance, installation, and exploded views for this unit type.
Lists detailed specifications like model, power, capacity, dimensions, and performance metrics.
Provides tables for amending cooling and heating capacity based on temperature conditions.
Shows dimensional drawings for various outdoor unit models.
Explains the cooling and heating cycles with system diagrams.
Details electrical wiring diagrams and connections for different outdoor unit models.
Provides exploded views and part lists for various outdoor unit models.
Covers preparation, installation precautions, site selection, and piping for outdoor units.
Explains the function and configuration of key air conditioner components like compressors and condensers.
Describes the function and configuration of electrical system components like PCB, fan motor, and contactors.
Explains common phenomena that might appear as malfunctions but are normal operating conditions.
Lists common failure phenomena and their potential causes or explanations.
Provides inspection methods for identifying malfunctions in electrical components using a multimeter.
Details failure codes for 220-240V and 380-415V unit power supplies.
Offers flowcharts for diagnosing and resolving specific failures like communication issues.
Describes available remote controllers, wired controllers, display panels, and receivers.
Explains the functions and button operations for the K series remote controller.
Covers basic conditions and functions for XK-01 and XK-02 wired controllers.
Provides resistance values for the 5K3470 sensor at various temperatures.
Lists resistance values for the 6.339K3954 exhaust temperature sensor across a temperature range.