AUX DC Inverter Free Match 50HZ R32
47
5.2 21K, 27K
DC INVERTER
Model
AM2-H21/4DR3
AM3-H27/4DR3
System Format
1 drive 3
1 drive 3
Capacity
Cooling
Btu/h
21154(7506~22895)
26955(7848~29650)
kW
6.2(2.2~6.71)
7.9(2.3~8.69)
Heating
Btu/h
22519(8155~24771)
27978(8359~30776)
kW
6.6(2.39~7.26)
8.2(2.45~9.02)
Electric Data
Power Supply
V~,Hz,P
h
220~240,50,1
220~240,50,1
Cooling Power
Input
W
1920350-2800
2460560-3400
Heating Power
Input
W
1780350-2800
2270560-3400
Rated Current
(cooling&heating)
A
8.3/7.8
10.7/9.8
Max current
A
13
16
Max power
KW
2.8
3.4
Performance
SEER/SCOP
W/W
6.57/4.38F
6.30/4.04F
SEER/SCOP
W/W
6.45/4.39L
6.29/4.04L
SEER/SCOP
W/W
6.57/4.39(J)
6.30/4.04(J)
Energy Rate
A++/A+
A++/A+
EER/COP
W/W
3.23/3.71
3.21/3.61
DC Inv.
Compressor
Model
KTN150D30UFZ
KTM240D57UKP
Quantity
1
1
Type
Twin Rotary
Twin Rotary
Brand
GMCC
GMCC
Capacity
W
4690
7715
Input
W
1250
2085
Power Supply
V~,Hz,P
h
220~240,50,1
220~240,50,1
Rated Current
A
7.1
9.5
Operating
Frequency
Hz
60
60
Frequency Range
8~120 Hz
12~120Hz
Refrigerant Oil
ml
VG74/450ml
VG74/670ml
Outdoor DC
Inverter Fan
Motor
Model
D-65-8
D-65-8
Type
DC Inverter
DC Inverter
Brand
WOLONG
WOLONG
Quantities
1
1
Insulation Class
E
E
Safe Class
IP24
IP24
Input Power
W
85
85
Output Power
W
65
65
Capacitor
uF
/
/
Speed
r/min
870-350
870-350
Outdoor Fan
Material
Plastic
Plastic

Table of Contents