which lasts more than 2 minutes, the compressor will stop
operating and the indoor fan will go by air quantity set.
10.3.3 When the compressor stops working, it can only be restarted
only if the temperature of indoor coiled pipe rises to more than 7
or the power-off of the compressor lasts more than 6 minutes.
10.4 Protection function of short or open circuit of temperature senor
10.4.1 Powered on, when it is detected that the T ring signal sent by
indoor environment temperature senor is abnormal, the air
conditioner will work under the mode of heating and will not be
powered off if the signal received from remote control is
“heating” or it will work under the mode of refrigeration and will
not be powered off if the signal received from remote control is
“refrigeration” or it will work for 8 minutes and then stop for 3
minutes with the wind speed of “mute cycle dehumidification” if
the signal received from remote control is “dehumidification”.
Besides, the signal of automatic mode sent by remote control
will not be effective, nor will the signal of automatic button
power-on and the related breakdown can be indicated at the
same time.
10.4.2 When it is detected that the T internal coiled pipe signal sent
by indoor coiled pipe temperature sensor is abnormal, the
freezing-proof, cold-wind-proof and overheat-proof functions