Beer Dispenser User’s Manual
- 1 -
User Manual
178UDD1HC, 178UDD2HC, 178UDD3HC, 178UDD4HC, 178UDD1HCS,
178UDD2HCS, 178UDD3HCS, 178UDD4HCS, 178UDD48HC, 178UDD48HCS,
178UDD60HC, 178UDD60HCS, 178UDD72HC, 178UDD72HCS,
Please read the manual thoroughly prior to equipment set-up,
operation and maintenance.
09/2017

Questions and Answers

  • F
    Frank CampbellAug 14, 2025
    Why is the condensing unit running for long periods in my Avantco Dispenser?
    • C
      coloncoreyAug 14, 2025
      If the condensing units of your Avantco Dispenser are running for extended periods, this could be due to several reasons. There might be too much water product inside, so allow enough time for it to cool down. Ensure doors are fully closed and not opened for too long. Check the door gaskets, making sure they're snapped in correctly; wash them with soap and water, and replace if needed. A dirty condenser coil can also cause this, so clean it. Finally, check for an iced-over evaporator coil; unplug the unit to defrost it, ensure the thermostat isn't too cold, and that door gaskets are sealing properly.
  • B
    Brittney RobertsAug 18, 2025
    What to do if the cabinet temperature is too warm in my Avantco Dispenser?
    • M
      Michael HoltAug 18, 2025
      If your Avantco Dispenser's cabinet temperature is too warm, try the following: First, adjust the thermostat to a lower temperature. Ensure proper airflow by rearranging the product inside, providing at least 4" of clearance from the evaporator. Allow warm products enough time to cool down before placing them inside. Check for blown fuses or tripped circuit breakers and replace or reset them as necessary. For low refrigerant levels, contact a service technician. Also, make sure the door isn't open for too long or ajar.
  • R
    rburgessAug 21, 2025
    How to fix a compressor that is not running on my Avantco Dispenser?
    • G
      George EricksonAug 21, 2025
      If the compressor in your Avantco Dispenser isn't running, check these items: * See if a fuse is blown or a circuit breaker is tripped; replace the fuse or reset the breaker. * Make sure the power cord is plugged in. * Verify the thermostat isn't set too high; set it to a lower temperature. * If the cabinet is in defrost cycle, wait for it to finish.
  • R
    Robert LoweAug 25, 2025
    Why is condensation collecting on the Avantco Dispenser?
    • R
      rachelericksonAug 25, 2025
      If condensation is collecting on your Avantco Dispenser's cabinet or floor, the gasket might not be sealing properly; clean, repair, or replace it as needed. Also, if the relative humidity is above 60%, move the unit to an area with lower humidity or lower the humidity level.
  • K
    krogersAug 28, 2025
    Why is the beer from my Avantco Dispenser flat and flavorless?
    • M
      Melissa MillsAug 28, 2025
      If the beer from your Avantco Dispenser is flat and lacks flavor, and the foamy head disappears quickly, it could be due to several factors. Ensure CO2 lines are always properly charged. Drain and refill the air source with clean air if it's contaminated. Clean glasses with a grease-cutting cleaner. Check for leaks and replace the air source if pressure is insufficient. Keep lines properly charged at all times, even overnight. Inspect lines for loose tap or vent connections and perform regular maintenance. Check connections on the pressure regulator and replace if sluggish. Finally, check for obstructions in the lines and clean them.
  • A
    Anthony SmithAug 31, 2025
    How to fix the interior light on my Avantco Dispenser?
    • A
      Angela DuffyAug 31, 2025
      If the interior light of your Avantco Dispenser isn't working, first, try turning the light switch off and on to check the switch connection. Then, ensure the bulb is correctly inserted in the socket. If it still doesn't work, replace the bulb.
  • P
    Patricia HansenSep 3, 2025
    Why is my Avantco Dispenser so noisy?
    • L
      Lisa WarnerSep 3, 2025
      If your Avantco Dispenser is making excessive noise, check for loose parts and tighten them. Also, ensure that the tubing isn't vibrating against other tubing or components.
  • M
    Misty ReevesSep 6, 2025
    Why does the beer from my Avantco Dispenser have a false head?
    • A
      Angela PinedaSep 6, 2025
      If the beer from your Avantco Dispenser has a false head with large, soap-like bubbles that dissolve quickly, it may be due to dry glasses; flush them with clean water and drain. Ensure you're pouring correctly: hold the glass at 45 degrees, pour at the midpoint, then tilt upright to 90 degrees, filling until there's a 1" to 1½" head. The pressure required may not match the beer temperature, so research proper temperatures and pressures for your draft product. Lastly, check that the air hose clip is in place and inspect the insulation for damage; repair as needed, as coils in beer lines might be warmer than the beer in the keg.
  • U
    udavisSep 10, 2025
    Why is the beer from my Avantco Dispenser all foam?
    • D
      David HughesSep 10, 2025
      If the beer from your Avantco Dispenser is all foam, ensure the keg wasn't agitated before tapping and that it's tapped quickly at the correct temperature. If the faucet is worn down, contact a trained maintenance worker. Check lines for kinks, dents, twists, or obstructions, ensuring they are clear and properly secured. The beer may be too warm in kegs or lines, so ensure the unit is set to the proper temperature, the air hose clip is in place, and insulation is undamaged. Finally, too much pressure can cause this, so ensure the unit operates at the ideal temperature for your product, check the pressure gauge, and inspect the air source.

Summary

Beer Dispenser Users Manual

Beer Dispenser Users Manual

Comprehensive guide for the setup, operation, and maintenance of Avantco beer dispensers.

General Safety Warnings

General Safety Warnings

Critical safety information regarding fire, explosion, and handling of flammable refrigerants.

Installation and Operation

Uncrating the Unit

Instructions for safely removing the unit from its packaging and preparing it for movement.

Electrical Instruction

Essential guidelines for safe and correct electrical hookup, including grounding and outlet requirements.

Draft Beer Tower Installation

Step-by-step process for installing the draft beer tower, including connecting lines and air hoses.

Regular Maintenance & Beer Setup

Cleaning the Bar System

Detailed instructions for cleaning beer lines, faucets, and components every two weeks.

Regular Maintenance

Cleaning the Condenser Coil

Importance and method for cleaning the condenser coil monthly to ensure efficient operation.

Troubleshooting Dispenser Issues

Compressor Not Running

Common causes and solutions for when the compressor fails to operate, checking fuses, cords, and thermostats.

Troubleshooting Draft Beer Issues

Flat Beer Problems

Diagnosing and fixing problems causing flat beer, like incorrect CO2 pressure or dirty lines.

False Head Problems

Addressing issues with excessive or dissolving foam, including glass preparation and pouring technique.

Wild Beer Problems

Resolving problems with beer dispensing as foam, such as improper tapping or temperature variations.

Avantco 178UDD4HC Specifications