- 16 -
User Manual
Dispenser Trouble Shooting
Compressor is Not Running
Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker.
Power cord unplugged. Plug in power cord.
Thermostat is at wrong temperature setting. Dial Controls: Set to higher number.
Digital Controls: Set to lower number.
Cabinet in defrost cycle. Wait for defrost cycle to finish.
Condensing Unit Runs for Long Periods of Time
Excessive amount of warm product placed in
cabinet.
Allow adequate time for product to cool down.
Prolonged door opening or door ajar. Ensure doors are closed when not in use.
Avoid opening doors for long periods of time.
Door gasket(s) not sealing properly. Ensure gaskets are snapped in completely.
Remove gasket and wash with soap and water.
Check condition of gasket and replace if necessary.
Dirty condenser coil. Clean the condenser coil.
Evaporator coil iced over. Unplug the unit and allow coil to defrost.
Make sure thermostat is not set too cold.
Ensure that door gasket(s) are sealing properly.
Cabinet Temperature is too Warm
Thermostat is at wrong temperature setting. Dial Controls: Set to higher number
Digital Controls: Set to lower number
Airflow is blocked. Re-arrange products to allow for proper air flow.
Make sure there is at least four inches of clearance
from the evaporator.
Excessive amount of warm product placed in cabinet. Allow adequate time for product to cool down.
Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker.
Dirty condenser coil. Clean the condenser coil.
Prolonged door opening or door ajar. Ensure doors are closed when not in use.
Avoid opening doors for long periods of time.
Evaporator coil iced over. Unplug the unit and allow coil to defrost.
Make sure thermostat is not set too cold.
Ensure that door gasket(s) are sealing properly.
Cabinet is Noisy
Loose parts. Locate and tighten loose part(s).
Tubing vibration. Ensure tubing is free from contact with other tubing
or components.