Normal mode
The procedure of the
normal mode
is :
1.
Connect
the meter to the adapter by the
USB-A male
port. Then plug-in a
constant-
current load(>500mA)
into the
USB-A female
port.
2.
Disconnect
the meter.
3.
Reconnect
the meter with an
A-C cable
or a
MicroUSB
cable
, then plug-in the
same
load in step1, the cable resistance will be
shown on the screen.
4-Line Mode
The device provides the
software
implementation
only
, require the usage of
the accessory from its provider.
Bypass Mode
This mode can only
evaluate
the resistance
of the Type-C 2 Type-C cable because the
meter can
only
get the resistance of the
positive line
inside the cable.